Free Heat Transfer Operations MCQs with Answers

645 Heat Transfer Operations MCQs from Chemical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.

Last updated

645 questions · page 28 of 33

  • A. Heat transfer co-efficient is proportional to 0.8th power
  • B. Pressure drop is proportional to the square
  • C. Neither A. nor B.
  • D. Both A. & B.

Explanation: For turbulent flow in the tube side, the heat-transfer coefficient commonly varies approximately as mass velocity to the 0.8 power, while…

Correct answer: Both A. & B.
  • A. 4 to 8
  • B. 3 to 5
  • C. 2 to 3
  • D. 6 to 12

Explanation: For liquid shell-and-tube heat exchangers, a tube length several times the shell diameter is preferred for economical design and…

Correct answer: 4 to 8
  • A. 25 cms
  • B. 40% of the I.D. of the shell
  • C. 5 cms
  • D. I.D. of the shell

Explanation: Baffle spacing should not be reduced below about 5 cm, because closer spacing increases shell-side pressure drop and makes fabrication and…

Correct answer: 5 cms
  • A. 0.3 to 0.8
  • B. 8 to12
  • C. 3.5 to 7.0
  • D. 1.25 to 3.125

Explanation: Corrugated plates for conventional plate heat exchangers are commonly specified in the approximate 1.25 to 3.125 mm range in this…

Correct answer: 1.25 to 3.125
  • A. 0.5 to 1
  • B. 1 to 1.5
  • C. 1.5 to 2
  • D. 2 to 2.5

Explanation: In a calandria evaporator, the downcomer or downtake cross-sectional area is typically about 0.5 to 1 times the total tube-flow area.

Correct answer: 0.5 to 1
  • A. 75% cut segmental baffle
  • B. 25% cut segmental baffle
  • C. Orifice baffle
  • D. Disk and doughnut baffle

Explanation: The 25% cut segmental baffle is the usual industrial choice because it provides effective cross-flow over the tubes without imposing…

Correct answer: 25% cut segmental baffle
  • A. Equal to
  • B. Half
  • C. One fourth
  • D. Three fourth

Explanation: The ligament is the clear distance between adjacent tubes, and standard exchanger practice takes its minimum as about one-fourth of the…

Correct answer: One fourth
  • A. 250
  • B. 450
  • C. 650
  • D. 750

Explanation: A vacuum of 650 mm Hg corresponds to an absolute pressure of about 110 mm Hg when atmospheric pressure is 760 mm Hg.

Correct answer: 650
  • A. Same as that for fluid flow
  • B. More than that for fluid flow
  • C. Less than that for fluid flow
  • D. D2 - D1 (D1 and D2 are I.D. of inner and outer pipes respectively)

Explanation: For annular flow, the heat-transfer hydraulic radius is based on the heat-transfer surface, whereas the flow hydraulic radius uses the…

Correct answer: More than that for fluid flow
  • A. Equal to the tube diameter
  • B. More than the tube diameter
  • C. Not less than one-fourth of the tube diameter or 3/16″
  • D. More in case of triangular pitch as compared to the square pitch tube layout

Explanation: Tube layout requires sufficient clearance for fabrication, cleaning, and fluid flow, generally at least one-fourth of the tube diameter or…

Correct answer: Not less than one-fourth of the tube diameter or 3/16″
  • A. Less than arithmetic mean value
  • B. More than arithmetic mean value
  • C. More than geometric mean value
  • D. Both B. & C.

Explanation: The logarithmic mean temperature difference lies between the geometric and arithmetic means, and the multipass correction factor further…

Correct answer: Less than arithmetic mean value
  • A. Both B. and C.
  • B. Not greater than
  • C. Not less than one fifth of
  • D. More than

Explanation: Shell-side baffle spacing is normally kept between about one-fifth of the shell inside diameter and the shell diameter.

Correct answer: Both B. and C.
  • A. 4(P2 - πd2/4)/πd
  • B. (P2 - rd2/4)/rd
  • C. 4P2/πd
  • D. πd/4P2

Explanation: Equivalent diameter is four times the flow area divided by the wetted perimeter.

Correct answer: 4(P2 - πd2/4)/πd
  • A. Same
  • B. Less
  • C. About 3 times
  • D. About 0.33 times

Explanation: For similar condensing conditions, condensate drains more effectively and the film resistance is lower on a horizontal condenser, giving a…

Correct answer: About 3 times
  • A. 15-20
  • B. 5-10
  • C. 30-35
  • D. 35-40

Explanation: Heat-transfer equipment is commonly given an overdesign allowance of about 15–20% to cover fouling, uncertainty in coefficients, and…

Correct answer: 15-20
  • A. Higher
  • B. Lower
  • C. Same
  • D. Unpredictable

Explanation: At equal mass velocity, gases generally have much lower film coefficients because their thermal conductivity and density are far lower…

Correct answer: Lower
  • A. Always less than the diameter of the tube
  • B. Called tube clearance
  • C. Called tube pitch
  • D. None of these

Explanation: Tube pitch is the centre-to-centre distance between adjacent tubes in a tube bundle.

Correct answer: Called tube pitch
  • A. Aluminium
  • B. Stainless steel
  • C. Copper
  • D. Carbon steel

Explanation: Copper has a higher thermal conductivity than aluminium, carbon steel, and stainless steel, so it gives the lowest tube-wall resistance…

Correct answer: Copper
  • A. Geometric mean of the true temperature difference and the LMTD
  • B. Ratio of LMTD to the true temperature difference
  • C. Differenced of true temperature difference and the LMTD
  • D. Ratio of true temperature difference to the LMTD

Explanation: For multipass or cross-flow exchangers, the actual mean temperature driving force is lower than the ideal countercurrent LMTD.

Correct answer: Ratio of true temperature difference to the LMTD