  • A. primary transmission
  • B. secondary transmission
  • C. primary distribution
  • D. secondary distribution

Explanation: A three-phase four-wire arrangement provides three phase conductors plus a neutral, allowing both three-phase loads and single-phase…

Correct answer: secondary distribution
  • A. dry weather
  • B. winter
  • C. summer heat
  • D. humid weather
  • E. none of the above

Explanation: Moist air contains ions and lowers the dielectric strength of the surrounding air, making ionisation and corona more likely.

Correct answer: humid weather
  • A. Quartz
  • B. Kaolin
  • C. Felspar
  • D. Silica

Explanation: Porcelain insulators are commonly made from kaolin, feldspar and quartz.

Correct answer: Silica
  • A. Steel cored aluminium
  • B. Galvanised steel
  • C. Cadmium copper
  • D. Any of the above

Explanation: Steel-cored aluminium, galvanised steel and cadmium copper have all been used as overhead-line conductors for different strength and…

Correct answer: Any of the above
  • A. corona losses are minimum
  • B. reactance is high
  • C. sending end voltage is more
  • D. receiving end voltage is more

Explanation: For a given system and sending conditions, reducing corona loss leaves more of the generated power available for transmission.

Correct answer: corona losses are minimum
  • A. distributors
  • B. generating stations
  • C. service mains
  • D. all of the above

Explanation: A feeder carries bulk power from a substation or generating source to distribution points, called distributors.

Correct answer: distributors
  • A. reduces power factor
  • B. corrodes the material
  • C. gives odour
  • D. transfer energy to the ground
  • E. none of the above

Explanation: Corona produces ozone, and ozone is a strong oxidising agent that attacks and corrodes metal and insulation materials.

Correct answer: corrodes the material
  • A. 400 V
  • B. 11 kV
  • C. 66 kV
  • D. 400 kV

Explanation: Large industrial consumers are commonly supplied at 11 kV to reduce current and distribution losses while avoiding the very high voltage…

Correct answer: 11 kV
  • A. 2 m
  • B. 3.5 m
  • C. 6 m
  • D. 8.5 m

Explanation: A 220 kV overhead line requires wider phase spacing to withstand its higher electric stress and limit flashover risk.

Correct answer: 6 m
  • A. 4.3 m
  • B. 5.5 m
  • C. 7.0 m
  • D. 10.5 m

Explanation: Higher-voltage lines need greater ground clearance for safety and to prevent flashover during normal operation or voltage surges.

Correct answer: 7.0 m
  • A. lead
  • B. rubber
  • C. copper
  • D. iron

Explanation: Lead is commonly used as an underground-cable sheath because it is impervious to moisture and provides good chemical and corrosion…

Correct answer: lead
  • A. aluminium
  • B. steel
  • C. brass
  • D. copper

Explanation: Steel is generally used for cable armour because its high mechanical strength protects the cable against impact, crushing and tension.

Correct answer: steel
  • A. copper
  • B. wood
  • C. R.C.C.
  • D. steel

Explanation: Transmission-line cross-arms are generally made of steel because it provides the required mechanical strength and durability for…

Correct answer: steel
  • A. copper conductors
  • B. all aluminium conductors
  • C. A.C.S.R. conductors
  • D. none of these

Explanation: ACSR combines aluminium strands, which give low weight and good conductivity, with a steel core that provides mechanical strength.

Correct answer: A.C.S.R. conductors
  • A. unity
  • B. lagging
  • C. leading
  • D. zero

Explanation: Industrial loads contain many induction motors and transformers, both of which draw magnetising current and therefore operate at a lagging…

Correct answer: lagging
  • A. balanced
  • B. unbalanced
  • C. either of the above
  • D. none of the above

Explanation: Distributor loads are usually spread unevenly among single-phase and three-phase consumers, so their phase currents are generally…

Correct answer: unbalanced
  • A. suspension insulators
  • B. pin insulators
  • C. both A. and B.
  • D. none of the above

Explanation: Suspension insulators are used on high-voltage transmission lines because strings of units can support greater voltage and mechanical…

Correct answer: suspension insulators
  • A. single phase
  • B. three-phase three wire
  • C. three-phase four wire
  • D. none of the above

Explanation: Residential distributors generally use a three-phase, four-wire system, with the neutral providing single-phase supply to homes and…

Correct answer: three-phase four wire
  • A. underground
  • B. overhead
  • C. either of the above
  • D. none of the above

Explanation: Most high-voltage transmission lines in Pakistan are overhead because overhead construction is much cheaper and easier to inspect and…

Correct answer: overhead
  • A. Radial system
  • B. Ring system
  • C. Inter-connected system
  • D. None of the above

Explanation: A radial distribution system has a single path from the source to each load, making its layout simple and its initial cost lowest.

Correct answer: Radial system