Free Power Systems MCQs with Answers
334 Power Systems MCQs from Electrical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.
Last updated
334 questions · page 1 of 17
- A. Above 220 kv
- B. Above 11kv
- C. Below 660 v
- D. Below 115 v
Explanation: Solid grounding is generally used on low-voltage systems, where the neutral is directly connected to earth and fault current can be safely…
Correct answer: Below 660 v- A. D.C voltage
- B. A.C voltage
- C. Half A.C voltage
- D. Half D.C voltageGet Study Guides
Explanation: AC voltage can be stepped up or down easily with transformers. High-voltage AC transmission carries the same power at lower current…
Correct answer: A.C voltage- A. 200 V D.C.
- B. 25 kV single phase A.C.
- C. 25 kV two phase A.C.
- D. 25 kV three phase A.C.
Explanation: The standard main-line railway electrification system for long-distance routes is 25 kV, single-phase AC at 50 Hz.
Correct answer: 25 kV single phase A.C.- A. ground fault on a cable
- B. short circuit fault on a cable
- C. both the ground fault and the short-circuit fault
- D. none of the above
Explanation: The Murray loop test uses a healthy conductor and a bridge arrangement to locate low-resistance faults such as earth faults and…
Correct answer: both the ground fault and the short-circuit fault- A. Adjustment of voltage at consumers premises within statutory limits
- B. Control of active and reactive power
- C. Adjustment of short period daily and seasonal voltage variations in accordance with variations of load
- D. All of the above
Explanation: Voltage control keeps consumer voltage within statutory limits, compensates for daily and seasonal load variations, and helps regulate…
Correct answer: All of the above- A. overhead telephone wire
- B. earth wire
- C. core wire of ACSR
- D. all of the above
Explanation: Steel provides high mechanical strength, so it is used for overhead telephone wires, earth wires, and the central reinforcing core of ACSR…
Correct answer: all of the above- A. Copper
- B. Aluminium
- C. Steel reinforced copper
- D. Steel reinforced aluminium
Explanation: Steel-reinforced aluminium conductors combine aluminium's low weight and good conductivity with steel's mechanical strength, making them…
Correct answer: Steel reinforced aluminium- A. Increases
- B. Decreases
- C. Remains unaffected
Explanation: In an ungrounded system, a single line-to-ground fault shifts the neutral potential.
Correct answer: Increases- A. transmission line
- B. motor
- C. generator
- D. feeder
Explanation: Transmission-line design must limit I²R losses because these losses waste generated power and reduce transmission efficiency.
Correct answer: transmission line- A. connecting lines in parallel
- B. connecting lines in series
- C. using machines of high impedance
- D. reducing the excitation of machines
- E. none of the above
Explanation: Parallel lines reduce the equivalent transfer reactance and increase the maximum power transfer, since Pmax is inversely proportional to…
Correct answer: connecting lines in parallel- A. compensate for line inductive reactance
- B. compensate for line capacitive reactance
- C. improve line voltage
- D. none of the above
Explanation: A series capacitor supplies capacitive reactance in series with the line, thereby cancelling part of the line's inductive reactance.
Correct answer: compensate for line inductive reactance- A. impedance
- B. directional
- C. non-directional
- D. none of the above
Explanation: An admittance relay, commonly called a mho relay, has a directional characteristic and responds to both impedance magnitude and phase…
Correct answer: directional- A. 100 microsecond
- B. 50 millisecond
- C. 0.5 sec
- D. 0.1 sec
Explanation: High-voltage air-blast circuit breakers are designed for rapid interruption, typically within about 50 milliseconds at this voltage level.
Correct answer: 50 millisecond- A. relay
- B. rewirable fuse
- C. H.R.C. only
- D. all of the above
Explanation: During a fault, the relay detects the abnormal condition and sends a trip signal to the circuit-breaker.
Correct answer: relay- A. zero sequence currents only
- B. positive sequence currents only
- C. negative and zero sequence currents
- D. zero, negative and positive sequence currents
Explanation: A balanced three-phase set has equal magnitudes separated by 120°, which forms a positive-sequence set only.
Correct answer: positive sequence currents only- A. no current flow
- B. heavy current flow
- C. voltage drop
- D. voltage rise
Explanation: A short circuit creates a very low-impedance path, so the current rises sharply and may become several times the normal load current.
Correct answer: heavy current flow- A. earth wires
- B. isolators
- C. H.R.C. fuses
- D. reactors
Explanation: Reactors add inductive reactance to the circuit, limiting the rate and magnitude of short-circuit current.
Correct answer: reactors- A. fault occurs on the bus itself
- B. fault occurs on neutral line
- C. two or more faults occur simultaneously
- D. fault occurs with respect to earthing
Explanation: In a single-bus arrangement, every circuit is connected to the same bus, so a bus fault can disconnect or shut down all connected…
Correct answer: fault occurs on the bus itself- A. distribution transformer
- B. generator transformer of the power plant
- C. auto-transformer of the power plant
- D. station transformer of the power plant
Explanation: Overfluxing protection is especially important for the generator transformer because excessive volts-per-hertz can saturate its magnetic…
Correct answer: generator transformer of the power plant- A. constant for all distances
- B. lower than that of if fault occurs away from the relay
- C. higher than that of if fault occurs away from the relay
- D. none of the above
Explanation: Interpreting “VII ratio” as the V/I impedance ratio, a fault nearer the impedance relay gives a shorter line impedance and therefore a…
Correct answer: lower than that of if fault occurs away from the relayPower Systems MCQs: common questions
Are these Power Systems MCQs free?
Yes. All Power Systems MCQs from Electrical Engineering are free on TestUstad, with unlimited attempts and no account needed. Nothing on this page is a sample or a trial.
How many Power Systems MCQs are on this page?
There are 334 Power Systems MCQs in the Electrical Engineering bank, shown 20 to a page with the correct answer and an explanation on each.
Does every Power Systems MCQ have an explanation?
Yes. Each Power Systems question shows the correct option and a written explanation of why it is correct, so a wrong answer teaches you something rather than just being marked wrong.
Can I take a timed Power Systems test?
Yes. The practice button on this page starts a free Power Systems test drawn from the Electrical Engineering bank. It marks each answer instantly, gives you a score at the end, and can be retaken as many times as you like.