Free Power Systems MCQs with Answers
334 Power Systems MCQs from Electrical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.
Last updated
334 questions · page 2 of 17
- A. Open circuit
- B. Short-circuit
- C. Long
- D. None of the above
Explanation: For an open-circuit termination, the reflected voltage is in phase with the incident voltage, giving a voltage reflection coefficient of…
Correct answer: Open circuit- A. Lightning arresters
- B. Relays
- C. Step-down transformer
- D. Switchgear
Explanation: A lightning arrester is connected at the line entry point to divert a travelling surge to earth before it reaches sensitive equipment.
Correct answer: Lightning arresters- A. Impedance
- B. Reactance
- C. Either of the above
- D. None of the above
Explanation: Impedance relays are commonly used for phase-fault protection, particularly on short and medium transmission lines.
Correct answer: Impedance- A. above 30 kVA.
- B. equal to and above 5 MVA
- C. equal to and above 25 MVA
- D. none of the above
Explanation: Transformer differential protection is normally applied to larger transformers because its cost and complexity are justified at higher…
Correct answer: equal to and above 5 MVA- A. hydro-electric generators
- B. steam turbine generators
- C. gas turbine generators
- D. all of the above
- E. none of the above
Explanation: Overvoltage protection is applied to generators of all these prime-mover types because excessive voltage can damage insulation and…
Correct answer: all of the above- A. Zero
- B. Unity
- C. Infinity
- D. None of the above
Explanation: The reflection coefficient is Γ = (ZL − Z0)/(ZL + Z0). When the load impedance equals the line surge impedance, the numerator is zero, so…
Correct answer: Zero- A. zero current
- B. maximum current
- C. minimum voltage
- D. maximum voltage
Explanation: An AC circuit-breaker arc naturally reaches its weakest point when the current passes through zero, allowing the dielectric strength…
Correct answer: zero current- A. single phase motors only
- B. two phase motors only
- C. two single phase motors running in parallel
- D. three phase motors
Explanation: Single phasing means one phase of a three-phase supply is lost, which can overheat and damage a three-phase motor.
Correct answer: three phase motors- A. low resistance
- B. high resistance
- C. low impedance
- D. high impedance
Explanation: A series reactor limits fault current mainly through its inductive reactance, so it should have high impedance but very low resistance to…
Correct answer: low resistance- A. Inductance
- B. Capacitance
- C. Resistance
- D. Reactance
Explanation: For a short transmission line, shunt capacitance is small because the line length is short, so it is neglected in the model.
Correct answer: Capacitance- A. generators
- B. busbars
- C. transformers
- D. motors
- E. all of the above
Explanation: Under-voltage relays can initiate protection or control actions in generators, busbars, transformers, and motors, such as tripping or load…
Correct answer: all of the above- A. Generators
- B. Motors
- C. Transmission line
- D. Transformers
Explanation: Negative-sequence current produces a reverse-rotating magnetic field that causes severe heating in generator rotors, so generators…
Correct answer: Generators- A. single bus
- B. double bus, double breaker
- C. main and transfer bus
- D. all of the above
Explanation: In a main-and-transfer-bus scheme, the bus coupler connects the main and transfer buses so a circuit can be shifted during breaker…
Correct answer: main and transfer bus- A. 11 kV
- B. 33 kV
- C. 60kV
- D. 110kV
Explanation: Outdoor substations become more economical and safer than indoor installations at higher voltages because large clearances and equipment…
Correct answer: 33 kV- A. single phase to ground faults
- B. phase to phase faults
- C. two phase to ground faults
- D. three phase faults
- E. any of these
Explanation: A short-circuit can occur from any listed fault, including phase-to-ground, phase-to-phase, two-phase-to-ground, or three-phase faults.
Correct answer: any of these- A. load flow
- B. load flow and short-circuit
- C. load flow and stability
- D. load flow, short-circuit and stability
- E. none of the above
Explanation: An A.C. network analyser models power-system operating conditions, including load-flow calculations, short-circuit studies and stability…
Correct answer: load flow, short-circuit and stability- A. reactors
- B. resistors
- C. capacitors
- D. none of the above
Explanation: Reactors add inductive reactance in series with the circuit, limiting the magnitude of short-circuit current.
Correct answer: reactors- A. current
- B. voltage
- C. impedance
- D. all of the above
Explanation: An induction-cup relay develops torque from the interaction of alternating magnetic fluxes, and its operation may be arranged to respond…
Correct answer: all of the above- A. zero
- B. infinity
- C. unity
- D. none of the above
Explanation: At an open circuit, the load impedance is infinite, so the voltage reflection coefficient is (ZL − Z0)/(ZL + Z0) = +1.
Correct answer: unity- A. lubricate the contacts
- B. insulate the contacts from switch body
- C. extinguish the arc
- D. all of the above
- E. none of the above
Explanation: When high-voltage switch contacts separate, an arc forms between them; the oil cools and deionises the arc path, helping extinguish it.
Correct answer: extinguish the arc