All Free Electrical Engineering MCQs with Answers

Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.

3,143 questions · page 142 of 158

  • A. impedance
  • B. directional
  • C. non-directional
  • D. none of the above

Explanation: An admittance relay, commonly called a mho relay, has a directional characteristic and responds to both impedance magnitude and phase…

Correct answer: directional
  • A. 100 microsecond
  • B. 50 millisecond
  • C. 0.5 sec
  • D. 0.1 sec

Explanation: High-voltage air-blast circuit breakers are designed for rapid interruption, typically within about 50 milliseconds at this voltage level.

Correct answer: 50 millisecond
  • A. relay
  • B. rewirable fuse
  • C. H.R.C. only
  • D. all of the above

Explanation: During a fault, the relay detects the abnormal condition and sends a trip signal to the circuit-breaker.

Correct answer: relay
  • A. zero sequence currents only
  • B. positive sequence currents only
  • C. negative and zero sequence currents
  • D. zero, negative and positive sequence currents

Explanation: A balanced three-phase set has equal magnitudes separated by 120°, which forms a positive-sequence set only.

Correct answer: positive sequence currents only
  • A. no current flow
  • B. heavy current flow
  • C. voltage drop
  • D. voltage rise

Explanation: A short circuit creates a very low-impedance path, so the current rises sharply and may become several times the normal load current.

Correct answer: heavy current flow
  • A. earth wires
  • B. isolators
  • C. H.R.C. fuses
  • D. reactors

Explanation: Reactors add inductive reactance to the circuit, limiting the rate and magnitude of short-circuit current.

Correct answer: reactors
  • A. fault occurs on the bus itself
  • B. fault occurs on neutral line
  • C. two or more faults occur simultaneously
  • D. fault occurs with respect to earthing

Explanation: In a single-bus arrangement, every circuit is connected to the same bus, so a bus fault can disconnect or shut down all connected…

Correct answer: fault occurs on the bus itself
  • A. distribution transformer
  • B. generator transformer of the power plant
  • C. auto-transformer of the power plant
  • D. station transformer of the power plant

Explanation: Overfluxing protection is especially important for the generator transformer because excessive volts-per-hertz can saturate its magnetic…

Correct answer: generator transformer of the power plant
  • A. constant for all distances
  • B. lower than that of if fault occurs away from the relay
  • C. higher than that of if fault occurs away from the relay
  • D. none of the above

Explanation: Interpreting “VII ratio” as the V/I impedance ratio, a fault nearer the impedance relay gives a shorter line impedance and therefore a…

Correct answer: lower than that of if fault occurs away from the relay
  • A. Open circuit
  • B. Short-circuit
  • C. Long
  • D. None of the above

Explanation: For an open-circuit termination, the reflected voltage is in phase with the incident voltage, giving a voltage reflection coefficient of…

Correct answer: Open circuit
  • A. Lightning arresters
  • B. Relays
  • C. Step-down transformer
  • D. Switchgear

Explanation: A lightning arrester is connected at the line entry point to divert a travelling surge to earth before it reaches sensitive equipment.

Correct answer: Lightning arresters
  • A. Impedance
  • B. Reactance
  • C. Either of the above
  • D. None of the above

Explanation: Impedance relays are commonly used for phase-fault protection, particularly on short and medium transmission lines.

Correct answer: Impedance
  • A. above 30 kVA.
  • B. equal to and above 5 MVA
  • C. equal to and above 25 MVA
  • D. none of the above

Explanation: Transformer differential protection is normally applied to larger transformers because its cost and complexity are justified at higher…

Correct answer: equal to and above 5 MVA
  • A. hydro-electric generators
  • B. steam turbine generators
  • C. gas turbine generators
  • D. all of the above
  • E. none of the above

Explanation: Overvoltage protection is applied to generators of all these prime-mover types because excessive voltage can damage insulation and…

Correct answer: all of the above
  • A. Zero
  • B. Unity
  • C. Infinity
  • D. None of the above

Explanation: The reflection coefficient is Γ = (ZL − Z0)/(ZL + Z0). When the load impedance equals the line surge impedance, the numerator is zero, so…

Correct answer: Zero
  • A. zero current
  • B. maximum current
  • C. minimum voltage
  • D. maximum voltage

Explanation: An AC circuit-breaker arc naturally reaches its weakest point when the current passes through zero, allowing the dielectric strength…

Correct answer: zero current
  • A. single phase motors only
  • B. two phase motors only
  • C. two single phase motors running in parallel
  • D. three phase motors

Explanation: Single phasing means one phase of a three-phase supply is lost, which can overheat and damage a three-phase motor.

Correct answer: three phase motors
  • A. low resistance
  • B. high resistance
  • C. low impedance
  • D. high impedance

Explanation: A series reactor limits fault current mainly through its inductive reactance, so it should have high impedance but very low resistance to…

Correct answer: low resistance
  • A. Inductance
  • B. Capacitance
  • C. Resistance
  • D. Reactance

Explanation: For a short transmission line, shunt capacitance is small because the line length is short, so it is neglected in the model.

Correct answer: Capacitance
  • A. generators
  • B. busbars
  • C. transformers
  • D. motors
  • E. all of the above

Explanation: Under-voltage relays can initiate protection or control actions in generators, busbars, transformers, and motors, such as tripping or load…

Correct answer: all of the above