All Free Electrical Engineering MCQs with Answers

Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.

3,143 questions · page 143 of 158

  • A. Generators
  • B. Motors
  • C. Transmission line
  • D. Transformers

Explanation: Negative-sequence current produces a reverse-rotating magnetic field that causes severe heating in generator rotors, so generators…

Correct answer: Generators
  • A. single bus
  • B. double bus, double breaker
  • C. main and transfer bus
  • D. all of the above

Explanation: In a main-and-transfer-bus scheme, the bus coupler connects the main and transfer buses so a circuit can be shifted during breaker…

Correct answer: main and transfer bus
  • A. 11 kV
  • B. 33 kV
  • C. 60kV
  • D. 110kV

Explanation: Outdoor substations become more economical and safer than indoor installations at higher voltages because large clearances and equipment…

Correct answer: 33 kV
  • A. single phase to ground faults
  • B. phase to phase faults
  • C. two phase to ground faults
  • D. three phase faults
  • E. any of these

Explanation: A short-circuit can occur from any listed fault, including phase-to-ground, phase-to-phase, two-phase-to-ground, or three-phase faults.

Correct answer: any of these
  • A. load flow
  • B. load flow and short-circuit
  • C. load flow and stability
  • D. load flow, short-circuit and stability
  • E. none of the above

Explanation: An A.C. network analyser models power-system operating conditions, including load-flow calculations, short-circuit studies and stability…

Correct answer: load flow, short-circuit and stability
  • A. reactors
  • B. resistors
  • C. capacitors
  • D. none of the above

Explanation: Reactors add inductive reactance in series with the circuit, limiting the magnitude of short-circuit current.

Correct answer: reactors
  • A. current
  • B. voltage
  • C. impedance
  • D. all of the above

Explanation: An induction-cup relay develops torque from the interaction of alternating magnetic fluxes, and its operation may be arranged to respond…

Correct answer: all of the above
  • A. zero
  • B. infinity
  • C. unity
  • D. none of the above

Explanation: At an open circuit, the load impedance is infinite, so the voltage reflection coefficient is (ZL − Z0)/(ZL + Z0) = +1.

Correct answer: unity
  • A. lubricate the contacts
  • B. insulate the contacts from switch body
  • C. extinguish the arc
  • D. all of the above
  • E. none of the above

Explanation: When high-voltage switch contacts separate, an arc forms between them; the oil cools and deionises the arc path, helping extinguish it.

Correct answer: extinguish the arc
  • A. thermocouple
  • B. electronic and bimetallic
  • C. both (A) and (B)
  • D. none of the above

Explanation: Low-power electrical equipment commonly uses electronic, bimetallic and thermocouple-based protective relays.

Correct answer: both (A) and (B)
  • A. 1 mega ohms
  • B. 10 mega ohms
  • C. 100 mega ohms
  • D. 500 mega ohms

Explanation: High-voltage circuit breakers require very high insulation resistance to prevent leakage and flashover across open contacts; the…

Correct answer: 100 mega ohms
  • A. interception
  • B. interception and conduction
  • C. interception, conduction and dissipation
  • D. interception, conduction, dissipation and reflection
  • E. none of the above

Explanation: Lightning protection must first intercept the stroke, conduct its current safely to earth, and dissipate the energy into the grounding…

Correct answer: interception, conduction and dissipation
  • A. power frequencies
  • B. higher frequencies entering generator or transformer units
  • C. either of the above
  • D. none of the above

Explanation: A wave trap, or line trap, presents high impedance to high-frequency carrier and surge signals while allowing normal power-frequency…

Correct answer: higher frequencies entering generator or transformer units
  • A. 33kVto66kV
  • B. HkVto33kV
  • C. 3.3kVandllkV
  • D. none of the above

Explanation: Resistance grounding is commonly applied to medium-voltage systems, particularly around 3.3 kV to 11 kV, to limit earth-fault current and…

Correct answer: 3.3kVandllkV
  • A. arc suppressing blow out coils
  • B. wide separation of the opened contacts
  • C. high speed opening of contacts
  • D. all of the above

Explanation: Large-current interruption requires rapid contact separation, sufficient contact gap, and arc-control devices such as blowout coils.

Correct answer: all of the above
  • A. in phase with the arc current
  • B. lagging the arc current by 90″
  • C. leading the arc current by 90°
  • D. none of the above

Explanation: The arc behaves approximately like a resistive element, so its voltage is substantially in phase with the arc current.

Correct answer: in phase with the arc current
  • A. slow making and breaking of load circuit contacts
  • B. foreign matter on the contact surface
  • C. too low contact pressure
  • D. all of the above

Explanation: Slow contact operation prolongs arcing, foreign material raises contact resistance, and insufficient pressure reduces the effective…

Correct answer: all of the above
  • A. short transmission line
  • B. medium transmission line
  • C. long transmission line
  • D. medium and long transmission lines

Explanation: For a short transmission line, shunt capacitance is small enough to neglect, leaving only the series impedance in the basic model.

Correct answer: short transmission line
  • A. high temperature
  • B. increase of mean free path
  • C. increasing field strength
  • D. all of the above

Explanation: Ionization is promoted by high temperature, which increases particle energy, a longer mean free path, which allows more ionizing…

Correct answer: all of the above
  • A. inrush protection
  • B. distance protection
  • C. time graded and current graded over current protection
  • D. both (B) and (C)
  • E. none of the above

Explanation: Transmission lines commonly use distance protection as the main protection, with time-graded or current-graded overcurrent protection as…

Correct answer: both (B) and (C)