Free Process Control and Instrumentation MCQs with Answers

254 Process Control and Instrumentation MCQs from Chemical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.

Last updated

254 questions · page 10 of 13

  • A. Triple point of hydrogen and freezing point of antimony
  • B. 13.81°K to 903.9°K
  • C. Neither A. nor B.
  • D. Both A. and B.

Explanation: The standard platinum resistance thermometer range extends from the triple point of hydrogen, 13.81 K, to the freezing point of antimony…

Correct answer: Both A. and B.
  • A. Critically damped
  • B. Overdamped
  • C. Underdamped
  • D. Highly fluctuating

Explanation: A damping ratio of unity means the two characteristic roots coincide on the negative real axis, giving the fastest response without…

Correct answer: Critically damped
  • A. Flow rates of granular solids
  • B. Flow rates of fluids
  • C. Very high temperature
  • D. Thermal conductivity of gases

Explanation: A hot-wire anemometer measures fluid velocity by detecting the cooling of a heated wire, and the velocity can be converted into flow rate.

Correct answer: Flow rates of fluids
  • A. Platinum-platinum + rhodium
  • B. Iron-constantan
  • C. Chromel-alumel
  • D. None of these

Explanation: A chromel-alumel thermocouple, also called Type K, develops roughly 31 to 33 mV at 800°C when referenced to 0°C.

Correct answer: Chromel-alumel
  • A. Lead
  • B. Nickel
  • C. Copper
  • D. 30% iron + 70% nickel

Explanation: Lead is not normally used as the sensing element of an industrial resistance thermometer because its resistance-temperature…

Correct answer: Lead
  • A. Chromel-alumel thermocouple
  • B. Optical pyrometer
  • C. Radiation pyrometer
  • D. Either B. or C.

Explanation: Molten iron and slag are too hot for ordinary contact thermometers, so non-contact optical or radiation pyrometers are used.

Correct answer: Either B. or C.
  • A. Decibel = 20 loge (AR)
  • B. Decibel = 20 log10 (AR)
  • C. Decibel = 20 log10 (AR)0.5
  • D. Decibel = 20 loge (AR)0.5

Explanation: For an amplitude ratio, the decibel value is defined as 20 times the base-10 logarithm of the ratio: dB = 20 log10(AR).

Correct answer: Decibel = 20 log10 (AR)
  • A. 12
  • B. 36
  • C. 54
  • D. 68

Explanation: Invar is an iron-nickel alloy containing approximately 36% nickel, which gives it an exceptionally low coefficient of thermal expansion.

Correct answer: 36
  • A. Liquid level under pressure
  • B. Frequency of light
  • C. Depression of freezing point
  • D. Rpm of a flywheel

Explanation: A stroboscope makes a rotating object appear stationary when the flashing frequency matches its rotational frequency, allowing its rpm to…

Correct answer: Rpm of a flywheel
  • A. Servo problem
  • B. Transient response
  • C. Frequency response
  • D. Regulator problem

Explanation: A control response caused by a change in set point is called a servo problem or servo response.

Correct answer: Servo problem
  • A. Thermal conductivity cell
  • B. Hot wire anemometer
  • C. Polarograph
  • D. Mass spectrometer

Explanation: A hot-wire anemometer measures fluid velocity or flow, not composition.

Correct answer: Hot wire anemometer
  • A. No change
  • B. Decrease
  • C. Exponential decrease
  • D. Increase

Explanation: Resistance follows R = ρL/A, so stretching increases the wire length while reducing its cross-sectional area.

Correct answer: Increase
  • A. Polarimeter
  • B. Polarograph
  • C. Dilatometer
  • D. Refractometer

Explanation: A polarimeter measures the rotation of plane-polarised light caused by an optically active solution.

Correct answer: Polarimeter
  • A. Platinum-rhodium
  • B. Tungsten-molybdenum
  • C. Chromel-alumel
  • D. Iron-constantan

Explanation: Tungsten-molybdenum thermocouples withstand higher temperatures than platinum-rhodium, chromel-alumel, and iron-constantan types.

Correct answer: Tungsten-molybdenum
  • A. Of cold junction only
  • B. Of hot junction only
  • C. Difference between hot and cold junctions
  • D. Difference between cold junction and atmospheric temperature

Explanation: Thermocouple emf is produced by the temperature difference between its hot and cold junctions, with the exact relation being nonlinear.

Correct answer: Difference between hot and cold junctions
  • A. Mercury in glass thermometer
  • B. Mercury in steel thermometer
  • C. Fused metal (Na or K) in steel thermometer
  • D. Alcohol in glass thermometer

Explanation: Alcohol remains liquid at much lower temperatures than mercury, so an alcohol-in-glass thermometer is used for low-temperature…

Correct answer: Alcohol in glass thermometer
  • A. Mercury
  • B. Water
  • C. Methyl alcohol
  • D. Carbon-tetrachloride

Explanation: Among the listed liquids, mercury has the smallest volumetric expansion coefficient under ordinary thermometer conditions.

Correct answer: Mercury
  • A. Pitot tube
  • B. Magnetic flowmeter
  • C. Flow nozzle type flowmeter
  • D. Turbine flowmeter

Explanation: A magnetic flowmeter measures conductive-fluid velocity through the voltage induced in the fluid by a magnetic field, so density…

Correct answer: Magnetic flowmeter
  • A. One cell
  • B. No cell
  • C. Three cells
  • D. Two cells

Explanation: A pH meter uses two electrode systems: a glass measuring electrode and a reference electrode, often assembled as a combined electrode.

Correct answer: Two cells
  • A. Peltier
  • B. Thomson
  • C. Seebeck
  • D. None of these

Explanation: The Peltier effect is the absorption or release of heat at the junction of two dissimilar conductors when current passes through it.

Correct answer: Peltier