Free Process Control and Instrumentation MCQs with Answers
254 Process Control and Instrumentation MCQs from Chemical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.
Last updated
254 questions · page 9 of 13
- A. Low loads
- B. High loads
- C. Temperature changes
- D. Flow rate changes
Explanation: A positioning controller gives an essentially on-off output, making it suitable for switching large or high-capacity loads where fine…
Correct answer: High loads- A. Load
- B. Controlled
- C. Manipulated
- D. None of these
Explanation: The heating or cooling-fluid flow rate is adjusted by the controller to influence shell temperature, so it is the manipulated variable.
Correct answer: Manipulated- A. d
- B. d2
- C. d3
- D. d4
Explanation: For a diaphragm of fixed material and thickness, deflection strongly depends on diameter and varies approximately with the fourth power of…
Correct answer: d4- A. Closed loop values vs. open loop values
- B. A.R. vs. phase lag of second order
- C. A.R. vs. phase lag of first order
- D. Frequency response values of controllers
Explanation: A Nichols chart relates open-loop gain and phase to the resulting closed-loop performance, with closed-loop magnitude contours…
Correct answer: Closed loop values vs. open loop values- A. Helical
- B. Semi-circular
- C. Circular
- D. Spiral
Explanation: Bourdon tubes are commonly formed as C-shaped, helical, or spiral tubes, while a circular form is not a standard configuration.
Correct answer: Circular- A. Piston type meter
- B. Rotameter
- C. Orifice and tapered plug meter
- D. Magnetic flow meter
Explanation: A magnetic flow meter determines flow from the voltage induced in a conductive fluid, so it does not use a changing flow area.
Correct answer: Magnetic flow meter- A. Introducing integral control
- B. Reducing value of Kc
- C. Introducing derivative control
- D. None of the above
Explanation: Proportional-only control leaves a steady-state offset when a sustained error is needed to produce the required output.
Correct answer: Introducing integral control- A. Velocity
- B. Time
- C. (Time)-1
- D. None of these
Explanation: A time constant characterizes how quickly a system responds, and its dimension is time.
Correct answer: Time- A. Ruth
- B. Mikhailov
- C. Nyquist
- D. None of these
Explanation: The Nyquist stability method assesses closed-loop stability from the frequency response of the open-loop transfer function.
Correct answer: Nyquist- A. Speed of response
- B. Reproducibility
- C. Fidelity
- D. Static characteristics
Explanation: Fidelity is the ability of an instrument to reproduce changes in the measured variable without dynamic error.
Correct answer: Fidelity171. Temperature measurement by optical pyrometer is done above ____________ point, which is 1063°C ?
- A. Gold
- B. Antimony
- C. Silver
- D. Nickel
Explanation: An optical pyrometer is generally used above the gold point, approximately 1063°C, where contact thermometers become unsuitable.
Correct answer: Gold- A. Iron-constantan
- B. Platinum-platinum + rhodium
- C. Copper-constantan
- D. Chromel-alumel
Explanation: A platinum-rhodium thermocouple withstands very high temperatures and oxidizing atmospheres, making it suitable near 1600°C.
Correct answer: Platinum-platinum + rhodium173. In an exothermic chemical reactor, the manipulated variable is the flow rate of_______________?
- A. Product
- B. Reactants
- C. Coolant
- D. None of these
Explanation: For temperature control in an exothermic reactor, coolant flow is commonly manipulated to remove more or less heat and maintain the…
Correct answer: Coolant- A. -10 to 20
- B. 400 - 1000
- C. 100 - 500
- D. 0 to 100
Explanation: A hydrogen constant-volume thermometer is commonly used over approximately 0 to 100°C, where hydrogen provides a useful reference gas.
Correct answer: 0 to 100- A. 1/(T2s2 + 2ξTs + 1)
- B. 1/(T2s2 + 2Ts + 1)
- C. 1/(T2s2 + 2ξT + 1)
- D. None of these
Explanation: The standard normalized second-order transfer function is 1/(T²s² + 2ξTs + 1), where T is the time constant and ξ is the damping ratio.
Correct answer: 1/(T2s2 + 2ξTs + 1)- A. Vapor pressure thermometer
- B. Mercury in glass thermometer
- C. Constant volume gas thermometer
- D. Resistance thermometer
Explanation: A mercury-in-glass thermometer gives a local visual reading and cannot conveniently transmit that reading over 60 metres.
Correct answer: Mercury in glass thermometer- A. < 100
- B. > 0
- C. < 0
- D. > 800
Explanation: Helium gas thermometers are particularly suitable for low-temperature measurements below 0°C because helium remains useful in the…
Correct answer: < 0- A. Bulb
- B. Bourdon tube
- C. Pointer
- D. None of these
Explanation: The bulb is the primary element because it senses temperature directly through the vapor-pressure change.
Correct answer: Bulb- A. A metal powder or graphite
- B. Air
- C. Oil
- D. Mercury
Explanation: Air is a poor heat-transfer medium and creates a large thermal resistance between the bulb and thermal well, slowing response.
Correct answer: Air- A. Alumel
- B. Chromel
- C. None of these
- D. Constantan
Explanation: Alumel and Chromel are nickel-containing alloys, while Constantan is a copper-nickel alloy and also contains nickel.
Correct answer: None of these