Free Heat Transfer Operations MCQs with Answers
645 Heat Transfer Operations MCQs from Chemical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.
Last updated
645 questions · page 25 of 33
- A. Increased steam economy
- B. Both A. and B.
- C. Decreased steam consumption
- D. Increased capacity
Explanation: In a multiple-effect evaporator, vapor from one effect heats the next effect, allowing the same steam to evaporate solvent repeatedly.
Correct answer: Both A. and B.- A. Both A. and B.
- B. Form friction
- C. Wall or skin friction
- D. Turbulent flow
Explanation: Heat-transfer and friction analogies relate wall shear stress to heat transfer at the fluid-solid interface, so they apply to skin or wall…
Correct answer: Wall or skin friction- A. U1 - U2
- B. U2 - U1
- C. 1/U2 - 1/U1
- D. 1/U1 - 1/U2
Explanation: The fouling resistance is the added thermal resistance caused by deposits, so 1/U_dirty = 1/U_clean + R_f.
Correct answer: 1/U1 - 1/U2- A. (1/U) Vs. (1/v0.8)
- B. (1/v0.8) Vs. U
- C. v0.8 Vs . U
- D. (1/U) Vs. (1/V)
Explanation: A Wilson plot linearizes the overall-resistance relation by plotting 1/U against the inverse velocity term, commonly 1/v^0.8.
Correct answer: (1/U) Vs. (1/v0.8)- A. 35.5
- B. 43.75
- C. 81.25
- D. 48.25
Explanation: At steady state, conduction through the wall equals convection from the oven air: (T_w − 25)k/l = (100 − T_w)(3k/l).
Correct answer: 81.25- A. Decreases the pressure drop
- B. Decreases the outlet temperature of cooling medium
- C. Increases the overall heat transfer coefficient
- D. None of these
Explanation: Multipassing increases the tube-side fluid velocity for the same flow rate and flow area per pass.
Correct answer: Increases the overall heat transfer coefficient- A. 1
- B. 2
- C. 3.5
- D. 5.5
Explanation: Calandria evaporators use relatively short vertical heating tubes, normally below about 2 m, to limit liquid head and circulation…
Correct answer: 2- A. 1.25
- B. 1.75
- C. 2.5
- D. 3.5
Explanation: The usual minimum tube pitch is about 1.25 times the tube outside diameter, providing enough ligament between adjacent tubes for…
Correct answer: 1.25- A. Results in higher shell side pressure drop
- B. Can accomodate less number of tubes for a given shell diameter
- C. Facilitates easier shell side cleaning; hence is more suitable for handling high dirt factor shell
- D. side fluid
- E. Creates relatively lower turbulence on the shell side resulting in lower shell side heat transfer
- F. co-efficient
Explanation: Triangular pitch places tubes closer together and forces the shell-side fluid through more tortuous passages, giving higher turbulence and…
Correct answer: Results in higher shell side pressure drop- A. Regenerative
- B. Finned
- C. Plate type
- D. Double pipe
Explanation: A double-pipe exchanger consists of one pipe inside another, with the flow reversing through a return leg in the common hairpin…
Correct answer: Double pipe- A. 4
- B. 1/2
- C. 2
- D. 1/4
Explanation: A 1-4 exchanger divides the same total tube flow among four passes, so the number of tubes carrying flow in each pass is one-fourth that…
Correct answer: 4- A. 8 : 1 to 12 : 1 for both liquid-liquid and gas-gas heat exchangers
- B. Both B. & C.
- C. < 4 : 1 for gas-gas exchangers
- D. 4 : 1 to 8 : 1 for liquid-liquid exchanger
Explanation: Liquid-liquid exchangers commonly use a tube-length-to-shell-diameter ratio of about 4:1 to 8:1.
Correct answer: Both B. & C.- A. nth
- B. 0.5 nth
- C. (1/n)th
- D. 1.5 nth
Explanation: For a fixed total heating surface, adding effects divides the available surface among the effects, so evaporation per unit surface is…
Correct answer: (1/n)th- A. Equal to
- B. Three fourth
- C. Half
- D. 1.5 times
Explanation: The tube sheet is normally made about equal in thickness to the tube outside diameter, subject to the stated minimum thickness of 22 mm.
Correct answer: Equal to- A. 1
- B. ∞
- C. 20.8
- D. 2
Explanation: Since tube-side film coefficient varies approximately as flow rate^0.8, the overall coefficient follows the same dependence only when…
Correct answer: 1496. When one of the fluids is highly corrosive and has fouling tendency, it should_____________________?
- A. Flow at a very slow velocity
- B. Preferably flow outside the tube
- C. Preferably flow inside the tube for its easier internal cleaning
- D. Flow outside the tube, when the flow is counter-current and inside the tube when the flow is
- E. co-current
Explanation: A corrosive, fouling fluid is preferably passed through the tubes because the tube side can be mechanically or chemically cleaned more…
Correct answer: Preferably flow inside the tube for its easier internal cleaning- A. Are easier to clean
- B. Are less prone to fouling
- C. Can be fitted into a smaller shell diameter hence the cost of the heat exchanger would be less
- D. None of these
Explanation: For the same heat-transfer area, smaller tubes provide more area per unit shell diameter, so the required shell can be smaller and…
Correct answer: Can be fitted into a smaller shell diameter hence the cost of the heat exchanger would be less- A. Tube dia of 2.5-7.5 cms, tube length of 75-200 cms and cylindrical drum dia of 1-6 metres are
- B. normally used
- C. Area of central downtake is equal to 40 to 100% of total cross-sectional area of the
- D. All A., B. & C.
- E. Liquor is inside the tube while the steam is outside the tube
- F. surrounding tube
Explanation: A short-tube calandria uses relatively short tubes with liquor inside the tubes and heating steam outside; the central downtake provides…
Correct answer: All A., B. & C.- A. 1.25-1.50 times
- B. Less than
- C. 2.5 times
- D. one-fourth of
Explanation: Tube pitch is commonly about 1.25 to 1.5 times the tube outside diameter, providing space for shell-side flow, fabrication, and tube…
Correct answer: 1.25-1.50 times- A. To increase the residence time of shell side fluid
- B. To increase the tube side heat transfer co-efficient by inducing turbulence
- C. To reduce the induced vibration in the tubes
- D. To provide support to the tube bundle
Explanation: Baffles increase shell-side residence time, support the tubes, and limit vibration by directing cross-flow.
Correct answer: To increase the tube side heat transfer co-efficient by inducing turbulence