All Free Electrical Engineering MCQs with Answers
Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.
3,143 questions · page 54 of 158
1061. In a capacitor start single-phase motor, when capacitor is replaced by a resistance____________?
- A. torque will increase
- B. the motor will consume less power
- C. motor will run in reverse direction
- D. motor will continue to run in same direction
Explanation: Replacing the capacitor with a resistance still creates a phase difference between the main and auxiliary winding currents, so the motor…
Correct answer: motor will continue to run in same direction- A. repulsion induction motor
- B. repulsion motor
- C. repulsion start induction run motor
- D. none of the above
Explanation: In a repulsion-start induction-run motor, the commutator and brushes provide repulsion starting torque, then a short-circuiter closes the…
Correct answer: repulsion start induction run motor- A. 95% to 99%
- B. 80% to 90%
- C. 50% to 75%
- D. 5% to 35%
Explanation: Shaded-pole motors have high rotor losses and weak starting torque, so their efficiency is very low, commonly about 5% to 35%.
Correct answer: 5% to 35%- A. short circuited capacitor
- B. capacitor value hiving changed
- C. open circuiting of capacitor
- D. none of the above
Explanation: A short-circuited capacitor removes the intended impedance and phase shift from the auxiliary circuit, causing excessive current in the…
Correct answer: short circuited capacitor- A. running winding only
- B. starting winding only
- C. either A. or (b)
- D. both A. and (b)
Explanation: The direction depends on the relative phase between the main and starting windings.
Correct answer: either A. or (b)- A. Split motor
- B. Shaded-pole motor
- C. Reluctance motor
- D. None of these
Explanation: A shaded-pole motor is inherently self-starting because the shading coil creates a weak sweeping magnetic field across each pole.
Correct answer: Shaded-pole motor- A. start and then stop
- B. start and run slowly
- C. start and run at rated speed
- D. not start at all
Explanation: The capacitor produces the phase lead needed to create starting torque in a capacitor-start motor.
Correct answer: not start at all- A. Repulsion motor
- B. Reluctance motor
- C. Hysteresis motor
- D. Universal motor
Explanation: Mixies require a compact motor with high speed and substantial starting torque, which is supplied by the universal motor.
Correct answer: Universal motor- A. disconnects auxiliary winding of the motor
- B. disconnects main winding of the motor
- C. reconnects the main winding the motor
- D. reconnects the auxiliary winding of the motor
Explanation: The auxiliary winding is needed mainly for starting, so the centrifugal switch disconnects it after the motor reaches a suitable speed.
Correct answer: disconnects auxiliary winding of the motor- A. at the end connections
- B. at the end terminals
- C. anywhere on the winding inside a slot
- D. at the slot edge where coil enters or comes out of the slot
Explanation: Mechanical vibration and electromagnetic forces can damage insulation where a coil enters or leaves a slot, making the slot edge the most…
Correct answer: at the slot edge where coil enters or comes out of the slot- A. 100 uF
- B. 200 uF
- C. 300 uF
- D. 400 uF
Explanation: Fractional-horsepower capacitor-start motors commonly use a relatively large starting capacitor, often around 200 to 300 microfarads.
Correct answer: 300 uF- A. is opposite to that of brush shift
- B. is the same as that of brush shift
- C. is independent of brush shift
Explanation: In a repulsion motor, shifting the brushes changes the direction of the armature current and hence the torque.
Correct answer: is the same as that of brush shift- A. run for about 1 minute
- B. run for about 5 minutes
- C. picked up about 50 to 70 per cent of rated speed
- D. picked up about 10 to 25 per cent of rated speed
Explanation: The starting winding is needed only during acceleration, so the centrifugal switch opens it after the rotor reaches roughly 50 to 70…
Correct answer: picked up about 50 to 70 per cent of rated speed- A. inductor
- B. capacitor
- C. resistor
- D. shading coils
Explanation: Shading coils are short-circuited copper rings placed around part of each pole.
Correct answer: shading coils- A. Universal motor
- B. Shaded pole type motor
- C. Capacitor start motor
- D. Capacitor start and run motor
Explanation: A universal motor operates on either AC or DC and provides both very high starting torque and high speed.
Correct answer: Universal motor- A. Capacitor run motor
- B. Shaded pole motor
- C. Capacitor start motor
- D. Split phase motor
Explanation: The running capacitor supplies the phase-shifted current continuously and improves the motor's power factor during operation.
Correct answer: Capacitor run motor- A. a single turn of heavy wire which is in parallel with running winding
- B. a single turn of heavy copper wire which is short-circuited and carries only induced current
- C. a multilayer fine gauge copper wire in parallel with running winding
- D. none of the above
Explanation: A shading coil is a single-turn thick copper ring that is short-circuited, so its current is produced by electromagnetic induction.
Correct answer: a single turn of heavy copper wire which is short-circuited and carries only induced current- A. more than i.he rated torque
- B. rated torque
- C. less than the rated torque
- D. zero
Explanation: A single-phase induction motor has two equal, oppositely rotating field components at standstill, whose torques cancel each other.
Correct answer: zero- A. the starting winding is connected through a centrifugal switch
- B. the running winding is connected through a centrifugal switch
- C. both starting and running windings are connected through a centrifugal switch
- D. centrifugal switch is used to control supply voltage
Explanation: In a split-phase motor, the centrifugal switch disconnects the high-resistance starting winding after the motor accelerates.
Correct answer: the starting winding is connected through a centrifugal switch- A. the motor will not start
- B. the motor will run
- C. the motor will run in reverse direction
- D. the motor will run in the same direction at reduced r.p.m
Explanation: Short-circuiting the capacitor removes the phase difference between the main and auxiliary winding currents, so the starting torque is…
Correct answer: the motor will not start