  • A. torque will increase
  • B. the motor will consume less power
  • C. motor will run in reverse direction
  • D. motor will continue to run in same direction

Explanation: Replacing the capacitor with a resistance still creates a phase difference between the main and auxiliary winding currents, so the motor…

Correct answer: motor will continue to run in same direction
  • A. repulsion induction motor
  • B. repulsion motor
  • C. repulsion start induction run motor
  • D. none of the above

Explanation: In a repulsion-start induction-run motor, the commutator and brushes provide repulsion starting torque, then a short-circuiter closes the…

Correct answer: repulsion start induction run motor
  • A. 95% to 99%
  • B. 80% to 90%
  • C. 50% to 75%
  • D. 5% to 35%

Explanation: Shaded-pole motors have high rotor losses and weak starting torque, so their efficiency is very low, commonly about 5% to 35%.

Correct answer: 5% to 35%
  • A. short circuited capacitor
  • B. capacitor value hiving changed
  • C. open circuiting of capacitor
  • D. none of the above

Explanation: A short-circuited capacitor removes the intended impedance and phase shift from the auxiliary circuit, causing excessive current in the…

Correct answer: short circuited capacitor
  • A. running winding only
  • B. starting winding only
  • C. either A. or (b)
  • D. both A. and (b)

Explanation: The direction depends on the relative phase between the main and starting windings.

Correct answer: either A. or (b)
  • A. Split motor
  • B. Shaded-pole motor
  • C. Reluctance motor
  • D. None of these

Explanation: A shaded-pole motor is inherently self-starting because the shading coil creates a weak sweeping magnetic field across each pole.

Correct answer: Shaded-pole motor
  • A. start and then stop
  • B. start and run slowly
  • C. start and run at rated speed
  • D. not start at all

Explanation: The capacitor produces the phase lead needed to create starting torque in a capacitor-start motor.

Correct answer: not start at all
  • A. Repulsion motor
  • B. Reluctance motor
  • C. Hysteresis motor
  • D. Universal motor

Explanation: Mixies require a compact motor with high speed and substantial starting torque, which is supplied by the universal motor.

Correct answer: Universal motor
  • A. disconnects auxiliary winding of the motor
  • B. disconnects main winding of the motor
  • C. reconnects the main winding the motor
  • D. reconnects the auxiliary winding of the motor

Explanation: The auxiliary winding is needed mainly for starting, so the centrifugal switch disconnects it after the motor reaches a suitable speed.

Correct answer: disconnects auxiliary winding of the motor
  • A. at the end connections
  • B. at the end terminals
  • C. anywhere on the winding inside a slot
  • D. at the slot edge where coil enters or comes out of the slot

Explanation: Mechanical vibration and electromagnetic forces can damage insulation where a coil enters or leaves a slot, making the slot edge the most…

Correct answer: at the slot edge where coil enters or comes out of the slot
  • A. 100 uF
  • B. 200 uF
  • C. 300 uF
  • D. 400 uF

Explanation: Fractional-horsepower capacitor-start motors commonly use a relatively large starting capacitor, often around 200 to 300 microfarads.

Correct answer: 300 uF
  • A. is opposite to that of brush shift
  • B. is the same as that of brush shift
  • C. is independent of brush shift

Explanation: In a repulsion motor, shifting the brushes changes the direction of the armature current and hence the torque.

Correct answer: is the same as that of brush shift
  • A. run for about 1 minute
  • B. run for about 5 minutes
  • C. picked up about 50 to 70 per cent of rated speed
  • D. picked up about 10 to 25 per cent of rated speed

Explanation: The starting winding is needed only during acceleration, so the centrifugal switch opens it after the rotor reaches roughly 50 to 70…

Correct answer: picked up about 50 to 70 per cent of rated speed
  • A. inductor
  • B. capacitor
  • C. resistor
  • D. shading coils

Explanation: Shading coils are short-circuited copper rings placed around part of each pole.

Correct answer: shading coils
  • A. Universal motor
  • B. Shaded pole type motor
  • C. Capacitor start motor
  • D. Capacitor start and run motor

Explanation: A universal motor operates on either AC or DC and provides both very high starting torque and high speed.

Correct answer: Universal motor
  • A. Capacitor run motor
  • B. Shaded pole motor
  • C. Capacitor start motor
  • D. Split phase motor

Explanation: The running capacitor supplies the phase-shifted current continuously and improves the motor's power factor during operation.

Correct answer: Capacitor run motor
  • A. a single turn of heavy wire which is in parallel with running winding
  • B. a single turn of heavy copper wire which is short-circuited and carries only induced current
  • C. a multilayer fine gauge copper wire in parallel with running winding
  • D. none of the above

Explanation: A shading coil is a single-turn thick copper ring that is short-circuited, so its current is produced by electromagnetic induction.

Correct answer: a single turn of heavy copper wire which is short-circuited and carries only induced current
  • A. more than i.he rated torque
  • B. rated torque
  • C. less than the rated torque
  • D. zero

Explanation: A single-phase induction motor has two equal, oppositely rotating field components at standstill, whose torques cancel each other.

Correct answer: zero
  • A. the starting winding is connected through a centrifugal switch
  • B. the running winding is connected through a centrifugal switch
  • C. both starting and running windings are connected through a centrifugal switch
  • D. centrifugal switch is used to control supply voltage

Explanation: In a split-phase motor, the centrifugal switch disconnects the high-resistance starting winding after the motor accelerates.

Correct answer: the starting winding is connected through a centrifugal switch
  • A. the motor will not start
  • B. the motor will run
  • C. the motor will run in reverse direction
  • D. the motor will run in the same direction at reduced r.p.m

Explanation: Short-circuiting the capacitor removes the phase difference between the main and auxiliary winding currents, so the starting torque is…