  • A. 10 to 15%
  • B. 30 to 40%
  • C. 50 to 60%
  • D. 60 to 70%

Explanation: Domestic appliances are used intermittently and their combined maximum demand is much higher than their average demand, so domestic load…

Correct answer: 10 to 15%
  • A. 15 years
  • B. 30 years
  • C. 60 years
  • D. 100 years

Explanation: Hydroelectric stations have very long service lives because their turbines, generators and civil structures are robust and can be…

Correct answer: 100 years
  • A. Direct stroke on line conductor
  • B. Indirect stroke on conductor
  • C. Direct stroke on tower top
  • D. Direct stroke on ground wire

Explanation: A direct stroke to a line conductor injects the lightning current directly into the electrical circuit, producing severe overvoltages and…

Correct answer: Direct stroke on line conductor
  • A. Easily damaged by high voltage
  • B. Cannot be repaired
  • C. Short service life
  • D. All of the above

Explanation: Static capacitors can be damaged by overvoltage, and an individual unit is normally replaced rather than repaired; their service life is…

Correct answer: All of the above
  • A. peak load plant
  • B. casual run plant
  • C. either A. or (b)
  • D. base load plant

Explanation: Efficiency matters least for a peak-load or casual-run plant because it operates for relatively few hours.

Correct answer: either A. or (b)
  • A. induction motors
  • B. synchronous motors
  • C. single phase motors
  • D. d.c. motors

Explanation: Induction motors draw magnetising current and therefore consume substantial reactive power, causing a lagging power factor in supply…

Correct answer: induction motors
  • A. peak demand
  • B. average demand
  • C. diversified demand
  • D. none of the above

Explanation: A load curve plots demand against time, so its highest ordinate is the maximum or peak demand reached during the period.

Correct answer: peak demand
  • A. peak load plants
  • B. base load plants
  • C. either A. or (b)
  • D. none of the above

Explanation: Base-load plants operate for long periods, so their high capital cost is spread over many generated units and their superior efficiency…

Correct answer: base load plants
  • A. 25 to 50 percent full load
  • B. 50 to 75 percent full load
  • C. full load
  • D. 25 percent overload

Explanation: Peak-load generators commonly achieve maximum efficiency below full load, typically around 50 to 75 percent of rated load.

Correct answer: 50 to 75 percent full load
  • A. Cost of wages
  • B. Cost of fuel
  • C. Cost of lubricants
  • D. All of the above

Explanation: Running cost is incurred during operation, including wages for operating staff, fuel consumption, and lubricants.

Correct answer: All of the above
  • A. kW
  • B. kWh
  • C. kVAR
  • D. none of the above

Explanation: A capacitor supplies reactive power, so its rating is expressed in kilovolt-amperes reactive, or kVAR.

Correct answer: kVAR
  • A. Nuclear
  • B. Hydro
  • C. Thermal
  • D. Diesel

Explanation: A hydroelectric station has no fuel cost and comparatively low operating and maintenance expenses after construction.

Correct answer: Hydro
  • A. Peak load plant
  • B. Base load plant
  • C. Nuclear power plant
  • D. Hydro electric plant

Explanation: A peak-load plant operates only when demand is high, so its average load remains below its maximum demand and its load factor cannot reach…

Correct answer: Peak load plant
  • A. fixed charges
  • B. operating or running charges
  • C. both A. and (b)
  • D. either A. or (b)

Explanation: In a two-part tariff, fixed charges depend mainly on maximum demand, whereas running charges depend on energy consumed.

Correct answer: operating or running charges
  • A. Load survey method
  • B. Mathematical method
  • C. Statistical method
  • D. Economic parameters

Explanation: Statistical methods estimate demand from previous consumption patterns, diversity, growth and seasonal variation.

Correct answer: Statistical method
  • A. Nuclear power plant
  • B. Hydro power plant
  • C. Steam power plant
  • D. Diesel power plant

Explanation: Steam plants generally have the lowest overall efficiency among these conventional options because several heat-conversion and mechanical…

Correct answer: Steam power plant
  • A. thermodynamic cycle
  • B. Rankin cycle
  • C. Vapor pressure cycle
  • D. Carton cycle

Explanation: Steam power stations operate on the Rankine cycle, in which water is pumped, heated into steam, expanded through a turbine, and then…

Correct answer: Rankin cycle
  • A. Thermal Power Plant
  • B. Hydro Power Plant
  • C. Nuclear Power Plant
  • D. Diesel Power Plant

Explanation: Hydro plants produce electricity without burning fuel, so they have very low direct air pollution during operation.

Correct answer: Hydro Power Plant
  • A. Nuclear power plants
  • B. Hydro-electric power plants
  • C. Thermal power plants
  • D. Diesel engine power plant

Explanation: Thermal plants usually require high maintenance because boilers, turbines, condensers, fuel-handling equipment, and pollution-control…

Correct answer: Thermal power plants
  • A. less than
  • B. equal to
  • C. greater than
  • D. none of the above

Explanation: Overall efficiency equals thermal efficiency multiplied by the efficiencies of the boiler, turbine, generator, and other auxiliaries.

Correct answer: less than