- A. Kc(1+ηD s)
- B. Kc(1 +1/ηD s)
- C. Kc ηD s
- D. Kc/ηD s
Explanation: A proportional-derivative controller has transfer function Gc(s)=Kc(1+τD s), where τD is the derivative time.
Correct answer: Kc(1+ηD s)- A. Q0(T0 - T) = Ac . h (dT/dt)
- B. Q0T0 - QT = Ac . h (dT/dt)
- C. Q(T0 - T) = Ac . h (dT/dt)
- D. Q(T0 - T) = Ac . (dTH/dt)
Explanation: For a perfectly mixed tank, the material balance removes the level-change term from the energy balance, leaving Ac h(dT/dt)=Q0(T0−T) after…
Correct answer: Q0(T0 - T) = Ac . h (dT/dt)- A. 1
- B. 2
- C. 3
- D. 4
Explanation: The number of root-locus branches equals the number of open-loop poles.
Correct answer: 3- A. Mercury in glass thermometer
- B. Nitrogen in steel thermometer
- C. Fused metal (Na or K) in steel thermometer
- D. Alcohol in glass thermometer
Explanation: Alcohol remains liquid at much lower temperatures than mercury, so an alcohol-in-glass thermometer has the lowest temperature range among…
Correct answer: Alcohol in glass thermometer- A. Volumetric expansion
- B. Pressure rise with temperature
- C. Linear expansion
- D. None of these
Explanation: Mercury expands nearly uniformly in volume when heated, and the capillary converts this volumetric expansion into a readable length or…
Correct answer: Volumetric expansion- A. Routh stability
- B. Nyquist
- C. Bode stability
- D. None of these
Explanation: The Bode stability criterion checks the gain at the phase-crossover frequency: a gain greater than unity indicates instability for the…
Correct answer: Bode stability- A. Radiation pyrometer
- B. Thermocouple
- C. Photo-electric pyrometer
- D. Platinum resistance thermometer
Explanation: A platinum resistance thermometer is generally limited to roughly 850 to 1000°C in routine use, whereas thermocouples and optical or…
Correct answer: Platinum resistance thermometer- A. Radiation pyrometer
- B. Mercury in glass thermometer
- C. Vapor pressure thermometer
- D. Platinum resistance thermometer
Explanation: A radiation pyrometer is primarily used for high-temperature, non-contact measurement and is not the usual instrument for sub-zero…
Correct answer: Radiation pyrometer- A. 20
- B. 30
- C. 40
- D. 50
Explanation: Liquid manometers are intended for relatively low differential pressures, and their practical maximum is commonly taken as about 30 psi.
Correct answer: 30- A. Thermal conductivity through the paper
- B. Magnetic susceptibility
- C. Electrical resistance through the paper
- D. None of these
Explanation: Water conducts electricity better than dry paper, so the electrical resistance of paper decreases as its moisture content increases.
Correct answer: Electrical resistance through the paper- A. Positive
- B. Atmospheric
- C. Very high
- D. Sub-atmospheric
Explanation: A McLeod gauge traps a known volume of gas and compresses it with mercury, allowing measurement of vacuum pressures below atmospheric…
Correct answer: Sub-atmospheric- A. 0°
- B. 45°
- C. 90°
- D. 180°
Explanation: At a phase lag of 180°, negative feedback effectively becomes positive feedback; if the open-loop gain is then greater than unity…
Correct answer: 180°- A. 250
- B. 350
- C. 550
- D. 700
Explanation: Pressurising the space above mercury with nitrogen suppresses mercury vapour formation and prevents separation of the mercury column…
Correct answer: 550- A. With the mercurial thermometer upto 350°C
- B. Directly
- C. All A., B. & C.
- D. Which is of higher magnitude
Explanation: Pyrometry is the measurement of high temperatures, generally by detecting thermal radiation without placing a sensor in direct contact…
Correct answer: Which is of higher magnitude- A. Optical pyrometer
- B. Radiation pyrometer
- C. Photoelectric pyrometer
- D. Thermocouples
Explanation: Optical, radiation, and photoelectric pyrometers are designed for non-contact measurement of red-hot objects in this high-temperature…
Correct answer: Thermocouples- A. Tank 3
- B. Tank 2
- C. Tank 1
- D. Tank 4
Explanation: The secondary sensor should detect the disturbance before it significantly affects the primary outlet temperature, while still being…
Correct answer: Tank 3- A. 1
- B. 1/√2
- C. 0.5
- D. 0.25
Explanation: For a first-order system, the amplitude ratio is 1/√[1+(ωη)²]. With ωη = 1, it becomes 1/√2.
Correct answer: 1/√2- A. 760.5
- B. 860.5
- C. 960.5
- D. 1060.5
Explanation: The silver point is the melting point of pure silver, traditionally taken as about 960.5°C in older calibration tables.
Correct answer: 960.5- A. s/(s2 - 1)
- B. s/(1 + s2)
- C. 1/(s2 - 1)
- D. 1/(s2 + 1)
Explanation: Using the standard transform pair, the Laplace transform of sin(at) is a/(s²+a²). Setting a = 1 gives 1/(s²+1).
Correct answer: 1/(s2 + 1)- A. Dielectrics
- B. Semi conductors
- C. Insulators
- D. Conductors
Explanation: Thermistors are made from semiconductor materials whose resistance changes greatly with temperature.
Correct answer: Semi conductors