All Free Electrical Engineering MCQs with Answers
Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.
3,143 questions · page 79 of 158
- A. Radiation
- B. Convection
- C. Conduction
- D. All of the above
Explanation: The fuse element transfers most of its generated heat to the surrounding filler and fuse body by conduction, which then carries it away.
Correct answer: Conduction- A. overload
- B. reverse current
- C. open-circuits
- D. short-circuits
Explanation: An H.R.C. fuse has a high rupturing capacity, so its enclosed fuse element and filling can safely interrupt very large fault currents.
Correct answer: short-circuits1563. Which of the following is the least expensive protection for overcurrent is low voltage system ?
- A. Rewireable fuse
- B. Isolator
- C. Oil circuit breaker
- D. Air break circuit breaker
- E. None of the above
Explanation: A rewireable fuse is the simplest and least costly low-voltage overcurrent device, since its fuse wire can be replaced after operation.
Correct answer: Rewireable fuse- A. motors
- B. power outlet circuits
- C. fluorescent lamps
- D. light circuits
Explanation: Delay or time-delay fuses tolerate the brief high inrush current drawn when a motor starts, while still operating during a sustained…
Correct answer: motors- A. 2
- B. 4
- C. 6
- D. 10
Explanation: A grounding conductor must have sufficient cross-sectional area to carry fault current safely without overheating; the stated minimum in…
Correct answer: 10- A. Inverse time trip
- B. Time-delay trip
- C. Shunt trip
- D. None of the above
- E. All of the above
Explanation: A shunt trip releases a circuit breaker when an external control voltage is applied, allowing it to be operated remotely.
Correct answer: Shunt trip- A. construct insulated cabins
- B. insulate the machinery
- C. ground the framework
- D. humidify the surroundings
Explanation: Connecting the machinery framework to earth provides a path for accumulated static charge to drain safely.
Correct answer: ground the framework- A. surface is moistened
- B. conductive dressing is done
- C. oil compound dressing is done
- D. talcum powder is sprayed on the surface
Explanation: A conductive dressing gives rubber or leather a slightly conductive surface so charges can leak away instead of accumulating.
Correct answer: conductive dressing is done- A. increases with rise in temperature
- B. increases with moisture content
- C. is same for all insulating materials
- D. none of the above
Explanation: Dielectric strength generally decreases as temperature or moisture increases, and it is different for different insulating materials.
Correct answer: none of the above- A. It will become magnetic
- B. It will melt
- C. It will get punctured or cracked
- D. Its molecular structure will get changed
Explanation: Applying a voltage above breakdown strength causes dielectric breakdown, which may puncture, crack, or otherwise permanently damage the…
Correct answer: It will get punctured or cracked- A. capacitor in parallel with contacts
- B. capacitor in series with each contact
- C. resistance in line
- D. none of the above
Explanation: A capacitor connected across the contacts provides a path for the sudden transient current and reduces the voltage rise that produces an…
Correct answer: capacitor in parallel with contacts- A. amount of moisture
- B. type of metals
- C. type of soil chemicals
- D. all above factors
Explanation: Underground corrosion is governed by moisture, the metals involved, and chemical composition of the surrounding soil.
Correct answer: all above factors- A. thin aluminium wires
- B. thin copper wires
- C. rigid cables
- D. flexible cables
Explanation: Vehicle battery connections must tolerate engine vibration and movement, so they are made with flexible cables rather than rigid…
Correct answer: flexible cables- A. goggles or other face shield
- B. rubber
- C. rubber boots and gloves
- D. all above safety devices
Explanation: Electrolyte, especially sulphuric acid, can seriously injure the eyes and skin, so face protection, rubber gloves and rubber boots are…
Correct answer: all above safety devices- A. the increase in length of the insulation
- B. the decrease in the length of the insulation
- C. either A. or (b)
- D. none of the above
Explanation: Insulation resistance is proportional to cable length, as given by R = ρl/A.
Correct answer: the increase in length of the insulation1576. Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ____________?
- A. Polyvinyle chloride
- B. Vulcanised rubber
- C. Impregnated paper
- D. Compressed SFe gas
- E. none of the above
Explanation: At extremely high voltages, compressed SF6 gas is preferred in gas-insulated cable systems because its high dielectric strength permits…
Correct answer: Compressed SFe gas- A. easy maintenance
- B. low cost
- C. can be used in congested areas
- D. can be used in high voltage circuits
Explanation: Underground cables require no overhead clearance and can be routed beneath streets, buildings and other congested locations.
Correct answer: can be used in congested areas- A. same at the conductor and the sheath
- B. minimum at the conductor and maximum at the sheath
- C. maximum at the conductor and minimum at the sheath
- D. zero at the conductor as well as on the sheath
- E. none of the above
Explanation: In a coaxial cable, electric stress is inversely proportional to the radius.
Correct answer: maximum at the conductor and minimum at the sheath- A. to minimise temperature stresses
- B. to avoid being unearthed easily due to removal of soil
- C. to minimize the effect of shocks and vibrations due to gassing vehicles, etc
- D. for all of the above reasons
Explanation: The principal reason for laying cables at sufficient depth is to protect them from shocks, vibrations and mechanical damage caused by road…
Correct answer: to minimize the effect of shocks and vibrations due to gassing vehicles, etc- A. 0.04 mm
- B. 0.2 to 0.4 mm
- C. 3 to 5 mm
- D. 40 to 60 mm
Explanation: Metallic shielding is normally made from a very thin metal tape or layer, commonly about 0.04 mm thick.
Correct answer: 0.04 mm