All Free Electrical Engineering MCQs with Answers

Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.

3,143 questions · page 75 of 158

  • A. to project against'internal fault
  • B. to reduce copper as well as core losses
  • C. to cool the transformer oil
  • D. to take care of the expansion and contraction of transformer oil due to variation of temperature of sur-roundings

Explanation: Transformer oil expands when heated and contracts when cooled. The conservator provides an oil reservoir to accommodate these volume…

Correct answer: to take care of the expansion and contraction of transformer oil due to variation of temperature of sur-roundings
  • A. 0.4 mm to 0.5 mm
  • B. 4 mm to 5 mm
  • C. 14 mm to 15 mm
  • D. 25 mm to 40 mm

Explanation: Transformer core laminations are typically about 0.35 to 0.5 mm thick, matching the 0.4 to 0.5 mm range given.

Correct answer: 0.4 mm to 0.5 mm
  • A. wood
  • B. copper
  • C. aluminium
  • D. silicon steel

Explanation: Silicon steel is used for transformer cores because its high electrical resistivity reduces eddy-current loss and its magnetic properties…

Correct answer: silicon steel
  • A. Bmax
  • B. Bmax1-6
  • C. Bmax1-83
  • D. B max

Explanation: By the Steinmetz relation, hysteresis loss is approximately proportional to Bmax^1.6, where Bmax is the maximum flux density.

Correct answer: Bmax1-6
  • A. magnetostrication
  • B. boo
  • C. hum
  • D. zoom

Explanation: The audible noise produced by magnetically induced lamination vibrations is called transformer hum.

Correct answer: hum
  • A. volts
  • B. amperes
  • C. kW
  • D. kVA

Explanation: Transformer capacity is rated in apparent power, S = VI, measured in VA or kVA.

Correct answer: kVA
  • A. asbestos fiber
  • B. silica sand
  • C. sodium chloride
  • D. silica gel

Explanation: Silica gel absorbs moisture from the air entering the transformer conservator, preventing the transformer oil and insulation from becoming…

Correct answer: silica gel
  • A. ionizing air
  • B. absorbing moisture
  • C. cleansing the transformer oil
  • D. cooling the transformer oil

Explanation: Breather material must absorb moisture from atmospheric air before it reaches the transformer oil.

Correct answer: absorbing moisture
  • A. reduces weight per kVA
  • B. reduces iron losses
  • C. reduces copper losses
  • D. increases part load efficiency

Explanation: For a given transformer rating, higher flux density permits a smaller iron core and therefore reduces the weight per kVA.

Correct answer: reduces weight per kVA
  • A. primary side
  • B. secondary side
  • C. low voltage side
  • D. high voltage side

Explanation: Tappings are normally placed on the high-voltage winding because it has more turns, allowing finer voltage adjustment, and carries lower…

Correct answer: high voltage side
  • A. The power factor of the two trans-formers will be different from the power factor of common load
  • B. Incorrect polarity will result in dead short circuit
  • C. The transformers will not share load in proportion to their kVA ratings
  • D. none of the above

Explanation: Connecting parallel transformers with opposite polarity places their induced voltages in opposition, producing a very large circulating…

Correct answer: Incorrect polarity will result in dead short circuit
  • A. leakage reactance
  • B. per unit impedance
  • C. efficiencies
  • D. ratings

Explanation: For parallel transformers, load division is governed mainly by their per-unit impedances.

Correct answer: per unit impedance
  • A. voltage device
  • B. current device
  • C. power device
  • D. main flux device

Explanation: A transformer operates as a constant-flux device because its applied voltage, frequency, and turns determine the core flux, which remains…

Correct answer: main flux device
  • A. to provide coupling between primary and secondary
  • B. to increase the magnitude of mutual flux
  • C. to decrease the magnitude of mag-netizing current
  • D. to provide all above features

Explanation: The iron core provides a low-reluctance path that links the primary and secondary, increases mutual flux, and reduces the magnetizing…

Correct answer: to provide all above features
  • A. less will be the secondary induced e.m.f.
  • B. less will be the primary induced e.m.f.
  • C. less will be the primary terminal voltage
  • D. none of the above

Explanation: Greater leakage flux increases the leakage reactance and causes a larger voltage drop in the secondary winding, reducing its induced…

Correct answer: less will be the secondary induced e.m.f.
  • A. to provide free passage to the cooling oil
  • B. to insulate the coils from each other
  • C. both A. and (b)
  • D. none of the above

Explanation: Spacers between adjacent transformer coils form channels through which cooling oil can circulate freely.

Correct answer: to provide free passage to the cooling oil
  • A. has high magnitude and low power factor
  • B. has high magnitude and high power factor
  • C. has small magnitude and high power factor
  • D. has small magnitude and low power factor

Explanation: At no load, a transformer draws only a small exciting current, most of which is magnetizing current and therefore reactive.

Correct answer: has small magnitude and low power factor
  • A. load on it increases
  • B. load on it decreases
  • C. load remains constant
  • D. none of the above

Explanation: When the load decreases, transformer losses and oil temperature fall, so the oil contracts and its volume decreases.

Correct answer: load on it decreases
  • A. at no load
  • B. at 50% full load
  • C. at 80% full load
  • D. at full load

Explanation: Distribution transformers remain energized continuously, so their design gives good efficiency at a moderate load rather than only at full…

Correct answer: at 50% full load
  • A. nearly full load
  • B. 70% full load
  • C. 50% full load
  • D. no load

Explanation: Power transformers generally operate near their rated load, so they are designed to have maximum efficiency near full load.

Correct answer: nearly full load