  • A. 0.555
  • B. 0.578
  • C. 0.5457
  • D. 0.6

Explanation: For superheated steam, using an isentropic exponent of about 1.3 gives a critical pressure ratio near 0.546.

Correct answer: 0.5457
  • A. 0.6
  • B. 0.578
  • C. 0.555
  • D. 0.5457

Explanation: For initially dry-saturated steam, the critical pressure ratio is approximately 0.577 to 0.578. Therefore, option b is the closest value.

Correct answer: 0.578
  • A. pvls=C
  • B. pv1126 = C
  • C. pv1A = C
  • D. pv = C

Explanation: Superheated steam behaves approximately like a gas during nozzle expansion, so its isentropic relation is commonly written as p v^1.3 = C.

Correct answer: pvls=C
  • A. series wound generator
  • B. shunt wound generator
  • C. synchronous generator
  • D. none of the above

Explanation: A booster is normally a series-wound generator connected in series with a feeder to compensate for voltage drop.

Correct answer: series wound generator
  • A. reactors
  • B. generators
  • C. transformers
  • D. all of the above

Explanation: Electromechanical voltage regulators, such as regulators used with alternators, adjust generator excitation to maintain terminal voltage.

Correct answer: generators
  • A. using reactors
  • B. increasing the load
  • C. adjusting the governor
  • D. reducing the terminal voltage
  • E. none of the above

Explanation: Generator frequency follows f = PN/120, so it increases when rotor speed is increased.

Correct answer: adjusting the governor
  • A. Its secondary current is 5 A
  • B. Its secondary voltage is 400 V
  • C. Its rating is 2 kVA
  • D. Its secondary current is 20 A
  • E. It is a step-up transformer

Explanation: For an ideal transformer, V₂/V₁ = N₂/N₁ = 2, so V₂ = 400 V, while current changes inversely to 5 A.

Correct answer: Its secondary current is 20 A
  • A. hysteresis and eddy current losses
  • B. friction and windage losses
  • C. copper losses
  • D. none of the above

Explanation: At fixed applied voltage and frequency, hysteresis and eddy-current losses depend mainly on the core flux and remain nearly constant as…

Correct answer: hysteresis and eddy current losses
  • A. friction and windage losses
  • B. magnetic losses
  • C. hysteresis and eddy current losses
  • D. copper losses

Explanation: Friction and windage losses require moving mechanical parts, so they occur in rotating machines but not in a stationary transformer.

Correct answer: friction and windage losses
  • A. eddy current loss will decrease
  • B. eddy current loss will increase
  • C. eddy current loss will remain unchanged
  • D. none of the above

Explanation: With applied voltage fixed, core flux is approximately proportional to 1/frequency.

Correct answer: eddy current loss will remain unchanged
  • A. to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns
  • B. to absorb the line surge voltage and save the winding of transformer from damage
  • C. to reflect the line surge and save the winding of a transformer from damage
  • D. none of the above

Explanation: A line surge produces a nonuniform voltage distribution in the end turns because of the winding's shunt capacitance, placing excessive…

Correct answer: to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns
  • A. core built-up of laminations of cold rolled grain oriented steel
  • B. core built-up of laminations of hot rolled sheet
  • C. either of the above
  • D. none of the above

Explanation: Cold-rolled grain-oriented steel provides high permeability along the grain direction and lower hysteresis and eddy-current losses than…

Correct answer: core built-up of laminations of cold rolled grain oriented steel
  • A. zoom
  • B. hum
  • C. ringing
  • D. buzz

Explanation: The familiar low-frequency noise of a transformer is called hum, mainly caused by magnetostriction and the resulting vibration of the core…

Correct answer: hum
  • A. Bushings
  • B. Core
  • C. Primary winding
  • D. Secondary winding

Explanation: Bushings pass the transformer conductors safely through the earthed tank and are mounted externally, so they can be seen from outside.

Correct answer: Bushings
  • A. Cellulose
  • B. Asbestos
  • C. Mica
  • D. Glass fibre

Explanation: Mica has excellent dielectric strength and a very high temperature capability, commonly associated with Class C insulation.

Correct answer: Mica
  • A. short-circuit test
  • B. back-to-back test
  • C. open circuit test
  • D. any of the above

Explanation: The back-to-back, or Sumpner, test uses two identical transformers to reproduce full-load conditions while measuring losses, temperature…

Correct answer: back-to-back test
  • A. Horn gaps
  • B. Thermal overload relays
  • C. Breather
  • D. Conservator

Explanation: Horn gaps provide a low-resistance path for lightning and switching surges, diverting them safely to earth.

Correct answer: Horn gaps
  • A. A good voltage regulation of a transformer means
  • B. output voltage fluctuation from no load to full load is least
  • C. output voltage fluctuation with power factor is least
  • D. difference between primary and secondary voltage is least
  • E. difference between primary and secondary voltage is maximum

Explanation: Good voltage regulation means the secondary-terminal voltage changes very little between no-load and full-load conditions.

Correct answer: output voltage fluctuation from no load to full load is least
  • A. 0.8 leading power factor
  • B. 0.8 lagging power factor
  • C. zero power factor
  • D. unity power factor

Explanation: With load current fixed, transformer losses are essentially fixed, while useful output is proportional to power factor.

Correct answer: unity power factor
  • A. on full-load
  • B. on overload
  • C. on leading power factor
  • D. on zero power factor

Explanation: At a leading power factor, the voltage drop caused by transformer leakage reactance can be offset by the resistive drop, bringing…

Correct answer: on leading power factor