All Free Electrical Engineering MCQs with Answers

Every Electrical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.

3,143 questions · page 61 of 158

  • A. sinusoidal
  • B. triangular
  • C. pulsating
  • D. flat topped

Explanation: At no load, the pole faces produce an approximately uniform flux density over much of the pole arc.

Correct answer: flat topped
  • A. armature reaction
  • B. armature resistance drop
  • C. field weakening due to armature reaction and armature
  • D. commutation

Explanation: Load voltage drops result from armature resistance, armature reaction, and the resulting reduction in field flux.

Correct answer: commutation
  • A. interpoles
  • B. dummy coils
  • C. compensating winding
  • D. shifting of axis of brushes

Explanation: Interpoles, compensating windings, and suitable brush shifting help neutralize the reactance emf during commutation.

Correct answer: dummy coils
  • A. there is no load on|he generator
  • B. the generator runs on full load
  • C. the generator runs on overload
  • D. the generator runs on designed speed

Explanation: With no armature current, armature reaction is absent, so the magnetic flux axis is not displaced.

Correct answer: there is no load on|he generator
  • A. negligibly low
  • B. equal to no-load terminal voltage
  • C. more than no-load terminal voltage
  • D. less than no-load terminal voltage

Explanation: A level-compounded generator is designed so that the series-field voltage rise compensates for armature-resistance and other internal…

Correct answer: equal to no-load terminal voltage
  • A. is the same as that of the main pole ahead
  • B. is the same as that of the immediately preceding pole
  • C. is opposite to that of the main pole ahead
  • D. is neutral as these poles do not play part in generating e.m.f.

Explanation: In a generator, each interpole has the same polarity as the main pole ahead of it in the direction of rotation.

Correct answer: is the same as that of the main pole ahead
  • A. almost zero
  • B. less than no load terminal voltage
  • C. more than no load terminal voltage
  • D. equal to no-load terminal voltage

Explanation: An over-compounded generator has a series-field voltage rise greater than the internal voltage drop as load increases.

Correct answer: more than no load terminal voltage
  • A. Series generator
  • B. Shunt generator
  • C. Compound generator
  • D. None of the above

Explanation: Self-excited series, shunt, and compound generators need residual magnetism to initiate the initial generated emf and field current.

Correct answer: None of the above
  • A. Series generator
  • B. Shunt generator
  • C. Compound generator
  • D. Separately excited generator

Explanation: A series generator has its field winding in series with the load, so at no load its field current is nearly zero and only a small residual…

Correct answer: Series generator
  • A. r.p.m. is more than 300
  • B. r.p.m. is less than 300
  • C. number of poles is 4
  • D. number of poles is 2

Explanation: Electrical angle equals mechanical angle multiplied by P/2, where P is the number of poles.

Correct answer: number of poles is 2
  • A. series generator
  • B. shunt generator
  • C. long shunt compound generator
  • D. any of'the above

Explanation: A long-shunt compound generator provides a comparatively steady charging voltage while supplying the varying current needed by an…

Correct answer: long shunt compound generator
  • A. voltage generated is less than the rated voltage
  • B. generated voltage is proportional to the load on the generator
  • C. voltage remains constant irrespective of the load
  • D. speed varies in proportion to the load on the generator

Explanation: In a flat-compounded generator, the series-field effect is adjusted to compensate for internal voltage drops as load changes.

Correct answer: voltage remains constant irrespective of the load
  • A. neutralise the commutating self induced e.m.f.
  • B. neutralise the armature reaction flux
  • C. neutralise both the armature reaction flux as well as commutating e.m.f. induced in the coil
  • D. perform none of the above functions

Explanation: Interpoles produce a commutating flux that opposes the armature-reaction flux in the commutation zone and induces a reversing emf to…

Correct answer: neutralise both the armature reaction flux as well as commutating e.m.f. induced in the coil
  • A. separately excited generator
  • B. shunt generator
  • C. series generator
  • D. compound generator

Explanation: A turbo-alternator commonly uses a DC shunt generator as its exciter because it supplies the field current required by the alternator.

Correct answer: shunt generator
  • A. to supply traction load
  • B. to supply industrial load at constant voltage
  • C. voltage at the toad end of the feeder
  • D. for none of the above purpose

Explanation: A series generator has a nearly constant current characteristic and is therefore used as a series booster to compensate for voltage drop…

Correct answer: voltage at the toad end of the feeder
  • A. increase
  • B. decrease
  • C. remain unaffected
  • D. fluctuate heavily

Explanation: Increasing the shunt-field resistance reduces field current and weakens the magnetic flux.

Correct answer: decrease
  • A. identified by the scarring of the commutator segment to which open circuited coil is connected
  • B. indicated by a spark completely around the commutator
  • C. both A. and (b)
  • D. none of the above

Explanation: An open armature coil interrupts current transfer at its associated commutator bars, producing scarring or burning there and abnormal…

Correct answer: both A. and (b)
  • A. any even number of conductors
  • B. any odd number of conductors
  • C. that even number which is exact multiple of poles + 2
  • D. that even number which is exact multiple of poles

Explanation: In a simplex lap winding, the coil and conductor arrangement requires an even total number of armature conductors so that the winding can…

Correct answer: any even number of conductors
  • A. brushes should be of proper grade and size
  • B. brushes should smoothly run in the holders
  • C. smooth, concentric commutator properly undercut
  • D. all of the above

Explanation: Good commutation depends on correctly sized and graded brushes, free brush movement in the holders, and a smooth, concentric, properly…

Correct answer: all of the above
  • A. total copper loss and mechanical loss
  • B. armature copper loss and iron loss
  • C. shunt field copper loss and mechanical loss
  • D. iron loss and mechanical loss

Explanation: Stray losses in a DC machine comprise core or iron losses and mechanical losses such as friction and windage.

Correct answer: iron loss and mechanical loss