981. When V is the applied voltage, then the breakdown torque of a synchronous motor varies as_________?
- A. V
- B. V312
- C. V2
- D. 1/V
Explanation: For a synchronous motor with constant excitation, the maximum or breakdown torque is proportional to the applied voltage, as shown by Tₘₐₓ…
Correct answer: V- A. no slip-rings
- B. one slip-ring
- C. two slip-rings
- D. three slip-rings
Explanation: The DC field winding of a conventional three-phase synchronous motor is supplied through two slip rings, one for each polarity.
Correct answer: two slip-rings983. In case one phase of a three-phase synchronous motor is short-circuited the motor will____________?
- A. not start
- B. run at 2/3 of synchronous speed
- C. run with excessive vibrations
- D. take less than the rated load
Explanation: A short-circuited phase creates severe current imbalance and prevents the motor from developing normal rotating-field conditions for…
Correct answer: not start- A. the direction of rotation is not fixed
- B. the direction of instantaneous torque reverses after half cycle
- C. startes cannot be used on these machines
- D. starting winding is not provided on the machines
Explanation: At standstill, the synchronous rotor cannot follow the rapidly reversing stator field.
Correct answer: the direction of instantaneous torque reverses after half cycle- A. voltage rating
- B. dielectric medium
- C. polarity marking
- D. definite value
Explanation: The alternating voltage reverses polarity, so the capacitor must be non-polarized and has no polarity marking.
Correct answer: polarity marking- A. spark excessively
- B. have poor efficiency
- C. have poor power factor
- D. all of the above
Explanation: A DC series motor on AC suffers from high reactance, poor power factor, reduced efficiency, and severe commutator sparking.
Correct answer: all of the above- A. through resistance
- B. through reactances
- C. through capacitors
- D. solidly
Explanation: AC series motors have poor commutation because of reactance, so resistance is commonly included in the armature-coil connections or leads…
Correct answer: through resistance- A. slip rings
- B. commutator
- C. both A. and (b)
- D. none of the above
Explanation: A repulsion motor requires a commutator and brush arrangement to produce the repulsion torque.
Correct answer: commutator- A. Repulsion motor
- B. Repulsion induction motor
- C. Repulsion start induction run motor
- D. None of the above
Explanation: A repulsion induction motor combines separate repulsion and induction arrangements, giving it two distinct windings for these operating…
Correct answer: Repulsion induction motor- A. centrifugal switch
- B. capacitor
- C. commutator
- D. all of the above
Explanation: A shaded-pole motor has no centrifugal switch, capacitor, or commutator because its starting torque comes from the shaded coil and delayed…
Correct answer: all of the above- A. disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding
- B. disconnect motor from supply and immediately reconnect it to supply with reversed connections of the main winding
- C. reverse the direction of connection of the auxiliary winding and after motor comes to rest then connect auxiliary winding to the supply
- D. reverse the direction of connections of the auxiliary winding and immediately connect it to supply
Explanation: Reversing a capacitor-start motor while it is rotating can cause severe current and mechanical stress, so it must first be disconnected…
Correct answer: disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding- A. become unstable
- B. draw excessive armature current and may burn out
- C. fall out of synchronism and come to stand still
- D. run as induction motor
Explanation: When the load exceeds the reluctance motor's pull-out torque, it loses synchronism and its squirrel-cage component allows it to continue…
Correct answer: run as induction motor- A. hard and annealed bearings
- B. ball or roller bearings
- C. soft and porous bearings
- D. plain or sleeve bearings
Explanation: Fractional-horsepower motors commonly use plain or sleeve bearings because they are inexpensive, compact, and adequate for moderate loads.
Correct answer: plain or sleeve bearings- A. open armature winding
- B. shorted armature winding
- C. shorted field winding"
- D. high commutator mica
- E. all of the above
Explanation: Brush sparking in a universal motor can result from armature winding faults, field winding faults, or high commutator mica that prevents…
Correct answer: all of the above- A. It is similar to reluctance motor
- B. It is basically an induction motor and not a synchronous one
- C. So far as its basic working principle is concerned, it is similar to shaded pole motor
- D. the air-gap between rotor and salient poles is non- uniform
Explanation: A reluctance-start motor is fundamentally an induction motor with a non-uniform air gap and salient rotor, and its starting action…
Correct answer: It is similar to reluctance motor996. If starting winding of a single-phase induction motor is left in the circuit, it will____________?
- A. run faster
- B. spark at light loads
- C. draw excessive current and overheat
- D. run slower
Explanation: The starting winding is designed for short-time operation; if it remains connected, it draws excessive current and overheats.
Correct answer: draw excessive current and overheat- A. motor will not come up to speed
- B. motor will not carry the load
- C. current drawn by the motor will be excessively high
- D. electrolytic capacitor will, in all probability, suffer break down
Explanation: If the switch fails to open, the electrolytic starting capacitor remains connected during running, where its alternating-current duty can…
Correct answer: electrolytic capacitor will, in all probability, suffer break down- A. It is a reversing motor
- B. It is preferred to permanent-split single-value capacitor motor where frequent reversals are required
- C. It has low starting as well as rushing currents
- D. It has high starting torque
Explanation: A two-value capacitor motor provides high starting torque with a large starting capacitor and efficient running with a smaller capacitor.
Correct answer: It is preferred to permanent-split single-value capacitor motor where frequent reversals are required999. If a single phase induction motor runs slower than normal, the most likely defect is_____________?
- A. worn bearings
- B. short-circuit in the winding
- C. open-circuit in the winding
- D. none of the above
Explanation: Worn bearings increase friction and can prevent the rotor from reaching its normal speed.
Correct answer: worn bearings- A. it is comparatively cheaper
- B. it has almost non-destructible capacitor
- C. it has low starting as well as running currents at relatively high power factor
- D. it is quiet in operation
Explanation: A two-value capacitor motor uses a large capacitor for starting and a smaller capacitor for running, giving high starting torque with…
Correct answer: it has low starting as well as running currents at relatively high power factor