  • A. Increased I R losses
  • B. Increased core losses
  • C. Poor commutation
  • D. Change in motor parameters
  • E. All of the above

Explanation: Thyristor bridge supplies produce ripple and harmonics in the motor current, causing higher copper and core losses and often poorer…

Correct answer: All of the above
  • A. less than
  • B. equal to
  • C. greater than
  • D. none of the above

Explanation: In the usual simplex lap-wound D.C. machine, one brush arm is provided for each pole, so the number of brush arms equals the number of…

Correct answer: equal to
  • A. worst, ventilation
  • B. poor ventilation
  • C. better ventilation
  • D. none of the above

Explanation: A large air gap leaves more space around the armature, allowing air to circulate more freely and improving ventilation.

Correct answer: better ventilation
  • A. between 5 to 10 mm
  • B. between 10 to 15 mm
  • C. between 15 to 20 mm
  • D. between 25 to 35 mm

Explanation: The usual D.C. armature slot pitch is kept around 25 to 35 mm. A very small pitch makes slots and teeth difficult to construct, while an…

Correct answer: between 25 to 35 mm
  • A. quiet
  • B. noisy
  • C. either of the above
  • D. none of the above

Explanation: A larger air gap reduces the magnetic pull between the stator and armature, which lowers vibration and magnetic noise. Thus, D.C.

Correct answer: quiet
  • A. equal to that of armature mmf
  • B. less in comparison with the armature mmf
  • C. large in comparison with the armature mmf
  • D. none of the above

Explanation: A strong field mmf dominates the armature mmf, so the armature reaction produces less relative distortion of the main field.

Correct answer: large in comparison with the armature mmf
  • A. 10 m/s
  • B. 20 m/s
  • C. 30 m/s
  • D. 40 m/s

Explanation: The peripheral speed of a conventional DC machine is normally limited to about 30 m/s to control centrifugal stress, vibration, and…

Correct answer: 30 m/s
  • A. increase
  • B. decrease
  • C. either of the above
  • D. none of the above

Explanation: For a given machine output, increasing the number of poles shortens the armature coil span and reduces the length of field coils, so less…

Correct answer: increase
  • A. 100 A
  • B. 200 A
  • C. 300 A
  • D. 400 A

Explanation: The current carried by one brush arm is normally limited to about 400 A to prevent excessive heating and current density at the brushes…

Correct answer: 400 A
  • A. 4 mm
  • B. 6 mm
  • C. 8 mm
  • D. 10 mm

Explanation: Ventilation ducts in DC machines are commonly assigned a width of about 10 mm.

Correct answer: 10 mm
  • A. increase
  • B. decrease
  • C. either of the above
  • D. none of the above

Explanation: Increasing field mmf requires larger field coils and more magnetic material to produce the required flux, which increases the machine's…

Correct answer: increase
  • A. Increase in length of air gap at pole tips
  • B. Increasing reluctance of pole tips
  • C. Compensating windings
  • D. Interpoles
  • E. All of the above

Explanation: Armature-reaction effects can be reduced by increasing pole-tip reluctance, using compensating windings, and using interpoles; a longer…

Correct answer: All of the above
  • A. between 2 to 4
  • B. between 6 to 8
  • C. between 9 to 16
  • D. between 20 to 30

Explanation: A practical DC armature commonly has about 9 to 16 slots per pole. This range provides enough conductors and commutator segments for…

Correct answer: between 9 to 16
  • A. 5 percent
  • B. 10 percent
  • C. 15 percent
  • D. 30 percent
  • E. none of the above

Explanation: With hot-rolled steel, the yoke is typically made about 15 percent larger in cross-sectional area than the core because its magnetic flux…

Correct answer: 15 percent
  • A. equal to 50 kVA
  • B. equal to 100 kVA
  • C. above 200 kVA
  • D. none of the above

Explanation: In the conventional classification used in such design questions, transformers above 200 kVA are called power transformers, while smaller…

Correct answer: above 200 kVA
  • A. Closed windings
  • B. Open windings
  • C. Either of the above
  • D. None of the above

Explanation: A closed armature winding forms a continuous electrical path through all coils, and its practical construction uses two coil sides per…

Correct answer: Closed windings
  • A. duplex winding
  • B. triplex winding
  • C. forced winding
  • D. none of the above

Explanation: A dummy coil is inserted in a wave winding when the slot or coil number does not satisfy the normal wave-winding condition; this…

Correct answer: forced winding
  • A. short pitch
  • B. full pitch
  • C. either of the above
  • D. none of the above

Explanation: A pole pitch is the distance between corresponding points of adjacent poles.

Correct answer: full pitch
  • A. front pitch
  • B. winding pitch
  • C. commutator pitch
  • D. back pitch

Explanation: Winding pitch is the distance, measured in coil sides, between the starts of successive coils.

Correct answer: winding pitch
  • A. small machines
  • B. large machines
  • C. either A. or B.
  • D. none of the above

Explanation: A dummy coil contributes no useful generated emf, so it wastes space and copper and is avoided in large machines where this loss becomes…

Correct answer: large machines