Free Process Control and Instrumentation MCQs with Answers
254 Process Control and Instrumentation MCQs from Chemical Engineering, each with the correct answer and a written explanation of why it is correct. Free and unlimited, with no account needed.
Last updated
254 questions · page 4 of 13
- A. Tubular reactor
- B. CSTR
- C. On-off controller
- D. None of these
Explanation: A tubular reactor is a distributed-parameter system because concentration and temperature vary continuously along its length.
Correct answer: Tubular reactor- A. Bubbler system
- B. Differential pressure manometer
- C. Diaphragm box system
- D. Air-trap system
Explanation: A differential-pressure manometer measures the pressure difference between the liquid side and the reference side; this difference is…
Correct answer: Differential pressure manometer- A. Steel
- B. Nichrome
- C. Vycor (a glass)
- D. Inconel
Explanation: Vycor has a thin, low-thermal-mass construction and gives a faster thermocouple response than the heavier metallic protection wells…
Correct answer: Vycor (a glass)- A. Increases
- B. Decreases
- C. Remain constant
- D. Increases exponentially
Explanation: Platinum has a positive temperature coefficient of resistance, so its resistance increases as temperature rises.
Correct answer: Decreases- A. Platinum resistance thermometer
- B. Thermocouple
- C. Optical pyrometer
- D. Bimetallic thermometer
Explanation: An optical pyrometer measures the radiation emitted by a hot surface without contacting it, making it suitable for a red-hot furnace.
Correct answer: Optical pyrometer- A. Phosphor bronze
- B. Monel metal
- C. Stainless steel
- D. Cast iron
Explanation: Bourdon tubes require elastic, corrosion-resistant metals such as phosphor bronze, Monel, or stainless steel.
Correct answer: Cast iron- A. Strip
- B. Diaphragm
- C. Bellow
- D. Bourdon tube
Explanation: Elastic pressure gauges commonly use Bourdon tubes, bellows, or diaphragms, whose deformation indicates pressure.
Correct answer: Strip- A. Radiation pyrometer
- B. platinum-platinum/rhodium thermocouple
- C. Iron-constantan thermocouple
- D. Platinum resistance thermometer
Explanation: The dome of a blast-furnace stove reaches very high temperatures, for which a platinum-platinum/rhodium thermocouple is suitable and…
Correct answer: platinum-platinum/rhodium thermocouple- A. Heat content of the system
- B. Liquid volume in the tank
- C. Level of liquid
- D. Flow rate
Explanation: In the hydraulic analogy, liquid level is the potential difference or voltage, while flow rate corresponds to current.
Correct answer: Level of liquid- A. Unstable
- B. Stable
- C. Critically damped
- D. None of these
Explanation: A negative gain margin means the loop would need a reduction in gain to reach the stability limit, indicating that the present closed-loop…
Correct answer: Unstable71. In a single tank system, the transfer function of level to inlet flow rate is__________________?
- A. R/TS
- B. R/(TS + 1)
- C. 1/TS
- D. None of these
Explanation: For a single tank, the level response to inlet flow is a first-order system: H(s)/Q(s) = R/(τs + 1), where τ is the time constant.
Correct answer: R/(TS + 1)- A. Copper-constantan
- B. Aluminium-Chromel
- C. Platinum-platinum + rhodium
- D. None of these
Explanation: A platinum-platinum/rhodium thermocouple, such as Type R or Type S, can measure temperatures around 1400°C.
Correct answer: Platinum-platinum + rhodium- A. Is 30°
- B. Is 90° at the most
- C. Is 120°
- D. Approaches 180° asymptotically
Explanation: A second-order denominator contributes a phase lag that increases toward 180° as frequency becomes very large.
Correct answer: Approaches 180° asymptotically- A. Reproducibility
- B. Dead zone
- C. Static error
- D. Time lag
Explanation: Time lag delays an instrument's response to a changing input, making it a harmful dynamic characteristic.
Correct answer: Time lag- A. > 1.7 and > 30°
- B. 30°
- C. < 1.7 and 1.7 and < 30°
Explanation: Common control-system design targets require a gain margin greater than about 1.7 and a phase margin greater than 30° to provide adequate…
Correct answer: > 1.7 and > 30°- A. Greater safety of operation
- B. All A., B. and C.
- C. Greater operation economy
- D. Better quality of product
Explanation: Plant instrumentation improves safety through monitoring and interlocks, product quality through tighter control, and operating economy by…
Correct answer: All A., B. and C.- A. Open
- B. Neither A. nor B.
- C. Either A. or B.
- D. Closed
Explanation: The Routh test examines the characteristic equation formed from the closed-loop denominator to determine pole stability.
Correct answer: Closed- A. Convert the primary signal into a more useful quantity, usually an electric impulse
- B. Amplify the input signal
- C. Modify the input signal
- D. Codify/decodify the input signal
Explanation: A transducer converts a measured physical quantity or primary signal into another usable form, commonly an electrical signal for…
Correct answer: Convert the primary signal into a more useful quantity, usually an electric impulse- A. -38.9
- B. -11.9
- C. -60.9
- D. -80.9
Explanation: Mercury freezes at approximately −38.9°C, so a mercury thermometer cannot provide a liquid-column reading below this temperature.
Correct answer: -38.9- A. 2.0
- B. 0.5
- C. 1.0
- D. 4.0
Explanation: Compare the denominator with s² + 2ζωₙs + ωₙ²: here ωₙ² = 4 gives ωₙ = 2, and 2ζωₙ = 2 gives ζ = 0.5. Thus the system is underdamped.
Correct answer: 0.5