All Free Chemical Engineering MCQs with Answers
Every Chemical Engineering question in the bank, across all chapters, each with the correct answer and a written explanation. Free and unlimited, with no account needed.
6,983 questions · page 341 of 350
- A. Copper-constantan
- B. Aluminium-Chromel
- C. Platinum-platinum + rhodium
- D. None of these
Explanation: A platinum-platinum/rhodium thermocouple, such as Type R or Type S, can measure temperatures around 1400°C.
Correct answer: Platinum-platinum + rhodium- A. Is 30°
- B. Is 90° at the most
- C. Is 120°
- D. Approaches 180° asymptotically
Explanation: A second-order denominator contributes a phase lag that increases toward 180° as frequency becomes very large.
Correct answer: Approaches 180° asymptotically- A. Reproducibility
- B. Dead zone
- C. Static error
- D. Time lag
Explanation: Time lag delays an instrument's response to a changing input, making it a harmful dynamic characteristic.
Correct answer: Time lag- A. > 1.7 and > 30°
- B. 30°
- C. < 1.7 and 1.7 and < 30°
Explanation: Common control-system design targets require a gain margin greater than about 1.7 and a phase margin greater than 30° to provide adequate…
Correct answer: > 1.7 and > 30°- A. Greater safety of operation
- B. All A., B. and C.
- C. Greater operation economy
- D. Better quality of product
Explanation: Plant instrumentation improves safety through monitoring and interlocks, product quality through tighter control, and operating economy by…
Correct answer: All A., B. and C.- A. Open
- B. Neither A. nor B.
- C. Either A. or B.
- D. Closed
Explanation: The Routh test examines the characteristic equation formed from the closed-loop denominator to determine pole stability.
Correct answer: Closed- A. Convert the primary signal into a more useful quantity, usually an electric impulse
- B. Amplify the input signal
- C. Modify the input signal
- D. Codify/decodify the input signal
Explanation: A transducer converts a measured physical quantity or primary signal into another usable form, commonly an electrical signal for…
Correct answer: Convert the primary signal into a more useful quantity, usually an electric impulse- A. -38.9
- B. -11.9
- C. -60.9
- D. -80.9
Explanation: Mercury freezes at approximately −38.9°C, so a mercury thermometer cannot provide a liquid-column reading below this temperature.
Correct answer: -38.9- A. 2.0
- B. 0.5
- C. 1.0
- D. 4.0
Explanation: Compare the denominator with s² + 2ζωₙs + ωₙ²: here ωₙ² = 4 gives ωₙ = 2, and 2ζωₙ = 2 gives ζ = 0.5. Thus the system is underdamped.
Correct answer: 0.5- A. Electrical conductivity
- B. Polarimetry
- C. Emission spectroscopy
- D. Dielectric constant end loss factor
Explanation: Water changes the dielectric constant and dielectric loss factor of an organic liquid substantially, allowing small amounts to be detected…
Correct answer: Dielectric constant end loss factor- A. Stefan Boltzmann law
- B. Kirchoff's law
- C. Wien's law
- D. Seebeck effect
Explanation: A radiation pyrometer determines temperature from the thermal radiation emitted by a hot body, commonly using the Stefan-Boltzmann…
Correct answer: Stefan Boltzmann law- A. P-I controller
- B. P-controller
- C. P-D controller
- D. P-I-D controller
Explanation: A proportional controller alone leaves a steady-state error, called offset, and its offset is not removed by derivative action.
Correct answer: P-controller- A. Mcleod gauge
- B. Alphatron
- C. Bourdon gauge
- D. Ionisation gauge
Explanation: An ionisation gauge is designed for very low pressures in the micron and sub-micron range by measuring ions produced in the gas.
Correct answer: Ionisation gauge- A. Non-linear relation of emf to temperature
- B. Corrosion resistance
- C. Oxidation resistance
- D. Linear relation of emf to temperature
Explanation: A useful industrial thermocouple should give an emf that changes nearly linearly with temperature, while resisting oxidation and…
Correct answer: Non-linear relation of emf to temperature- A. Seebeck effect
- B. Peltier effect
- C. Joule heating effect
- D. Thomson effect
Explanation: The Peltier effect is the absorption or liberation of heat at a junction when current passes through it.
Correct answer: Peltier effect- A. Chromatograph
- B. Polarograph
- C. Polarimeter
- D. Spectrometer
Explanation: A polarimeter measures optical rotation by passing polarized light through a sample and determining the angle of rotation.
Correct answer: Polarimeter- A. Kc(1 + ηis + ηD ). s
- B. None of these
- C. Kc(1 + ηis + (1/ηD . s)
- D. Kc[1 + (1/ηis) + ηD . s)
Explanation: The ideal PID controller is written as Kc[1 + 1/(ηi s) + ηD s], combining proportional, integral, and derivative actions.
Correct answer: Kc[1 + (1/ηis) + ηD . s)- A. Thermal conductivity cell
- B. X-ray diffraction
- C. Mass spectrometer
- D. Emission spectrometer
Explanation: A thermal conductivity cell compares the thermal conductivity of a gas sample with a reference gas, making it useful for continuous gas…
Correct answer: Thermal conductivity cell- A. Weight
- B. Stress
- C. Strain
- D. Velocity
Explanation: A load cell converts the force produced by a load into an electrical signal, so it is commonly used to measure weight.
Correct answer: Weight- A. Teflon
- B. Asbestos
- C. Ceramic fibre
- D. Fibre glass
Explanation: Ceramic fibre withstands much higher temperatures than Teflon, asbestos, or fibreglass, so it provides the highest temperature rating…
Correct answer: Ceramic fibre